Common Failures of Salt Spray Environmental Chambers
When you encounter some common failures of salt spray environmental chambers, how to solve them? Wuxi Guanya Refrigeration Technology Co., Ltd. has brought the relevant fault tips as follows.
Salt spray environmental chamber cannot spray
Failure causes: 1. air compressor does not work; 2. main switch of the air compressor outlet does not open; 3. solenoid valve malfunctions; 4. pressure meter malfunctions or the pressure is too low; 5. electromagnetic contactor malfunctions; 6. nozzle blocks;
Handling methods: 1. open the air compressor; 2. open the main switch of the air compressor; 3.4.5. ask the after-sales department for door-to-door repair service; 6. remove the nozzle and clean it (please carefully disassemble).
The temperature of the saturation tank of the salt spray environmental chamber cannot rise to the set temperature
Failure causes: 1. the temperature of the temperature controller of the saturation tank is too low; 2. the temperature of the saturation bucket safety protection switch is set too low; 3. heating system malfunctions; 4. electromagnetic relay malfunctions; 5. controller malfunctions.
Handling methods: 1. Set the temperature of the temperature controller to the required temperature; 2. Set the temperature of the safety switch to the required temperature; 3. Ask the after-sales department for door-to-door repair service.
Lack of spray amount in the salt spray environmental chamber
Failure causes: 1. spray regulator is placed too low; 2. glass filter pf the preheating tank is blocked; 3. pressure is set too low.
Handling methods: 1. raise the spray regulator; 2. clean up the glass filter; 3. adjust the pressure of the pressure valve to 1Kg/cm², the air compressor is marked with a pressure valve, adjust to the pressure to 2Kg/cm².
These are some handling methods of the salt spray environmental chamber failures brought by Wuxi LNEYA. Wuxi LNEYA has environmental chambers for sale, the quality and the after-sales are guaranteed.
Related recommendations
-
Analysis of the environmental requirements of the -20 °C freezer
2222Due to the difference in ambient temperature, there are certain requirements for the freezer. Today LNEYA came to tell you how the ambient temperature is good for the -20 °C freezer. Now there are many types of freezer boxes: hot and cold temperat...
View details -
Trouble shooting method for refrigeration device of air-cooled cold water mechanism chemical reactio
2396If air enters into the air-cooled coldwater mechanism refrigeration unit system of the chemical reaction kettle, theimpact will be many. Enter the air circulation system first, the pressure willrise, the heat dissipation effect of the condenser...
View details -
Importance Of The Low Temperature Chamber
1947The low temperature chamber is a large cryogenic or high-cryogenic test device, which usually separates the refrigerator from the test part and makes the test part into a room type, so the staff can work in it. Such a test room is called a low tem...
View details -
Precautions for the replacement of refrigerating oil in the cooling system of the vehicle charger
2086The cooling system of the on-board charger should pay attention to the condition of the refrigerating oil during the operation. After the compressor is started, carefully observe the changes in the oil temperature and oil pressure. If the oil chan...
View details
LNEYA Thermo Refrigeration Co.,Ltd