Usage Details of High and Low Temperature Environmental Chambers
The enterprise users must have a certain understanding of the functions of the high and low-temperature environmental chamber after using them for a long time, but something detail of the high and low-temperature environmental chamber may still not be paid attention to, so the technology department of Wuxi LNEYA has specially reorganized the related matters of attention for everyone.
Professional manufacturer of high and low-temperature environmental chambers for sale
When delivering, the tilted angle of the high and low-temperature environmental chamber should not exceed 30°. When carrying, keep the body of the high and low-temperature environmental chamber vertically, do not place it inversely or horizontally. Besides, dragging the door handle or the condenser are prohibited, otherwise, the equipment may be damaged.
The high and low-temperature environmental chamber should be electrified regularly every month during the lengthy shutdown period, and the power-on time should be more than 1h.
Professional manufacturers of high and low-temperature environmental chamber insist on taking out the test samples after each test and wipe the workroom wall of the environmental chamber to keep the inner box clean.
Cleaning and balance of the circulating blade and condenser fan: Similar to that of the cleaning evaporator, because the working environment of the environmental chamber is different, a lot of small particles like dust will condense on the circulating blade and condenser fan. Hence, they should be cleaned regularly.
The power supply voltage of the high and low-temperature environmental chamber fluctuations, such as repeated power failure. In this case, it is suggested to suspend the use of high and low-temperature environmental chamber and close the power supply to prevent the burning of the compressor. Do not start the compressor immediately after the shutdown of the high and low-temperature environmental chamber. It should be stopped for 2-5 minutes before restarting.
The condenser of the high and low-temperature environmental chamber should be cleaned every three months. The condensing fan should be regularly overhauled and the condenser should be cleaned and dedusted so as to ensure its good ventilation and heat transfer performance.
High and low-temperature environmental chamber should be placed in a well-ventilated position with low humidity and smooth ground, 60 ~ 70 cm of use and maintenance space should be left around.
During the operation of high and low-temperature environmental chamber, the frequency of door opening should be minimized and the spillage of cold air should be reduced.
The usage details of high and low-temperature environmental chamber should be used by enterprise users in daily use.
Related recommendations
-
[Invited to visit] CPHI CHINA 2019, Wuxi Guanya W5P22 booth is looking forward to your arrival!
2347On June 18-20, 2019, the 19th World Pharmaceutical Raw Materials China Exhibition - CPhI China 2019 will re-enter Shanghai New International Expo Center. CPhI China World Pharmaceutical Raw Materials China Exhibition is an international, high-qual...
View details -
Effect of evaporator on refrigeration system in special instrument for low temperature experiment
2303The low temperature experiment special instrument is LNEYA's refrigeration heating equipment for the laboratory. The importance of the evaporator is self-evident. So what effect does the evaporator have on the refrigeration system? According to di...
View details -
How to choose the optimal chiller solution?
1908Choosing a water chiller is like finding a "target" for an enterprise's production equipment. It must not only be "like-minded", but also "be well-matched". The one that suits you is the best. If the choice is not good, either the cooling effect ...
View details -
How to troubleshoot the failure of the material aging test chiller?
2350Regular maintenance work for the material aging test chiller, and troubleshooting is also very important. 1. Exhaust at double high pressure, heat dissipation may be problematic. When it is detected that the high and low pressure of the system are...
View details
LNEYA Thermo Refrigeration Co.,Ltd