Usage Details of High and Low Temperature Environmental Chambers
The enterprise users must have a certain understanding of the functions of the high and low-temperature environmental chamber after using them for a long time, but something detail of the high and low-temperature environmental chamber may still not be paid attention to, so the technology department of Wuxi LNEYA has specially reorganized the related matters of attention for everyone.
Professional manufacturer of high and low-temperature 환경 챔버 판매
When delivering, the tilted angle of the high and low-temperature environmental chamber should not exceed 30°. When carrying, keep the body of the high and low-temperature environmental chamber vertically, do not place it inversely or horizontally. Besides, dragging the door handle or the condenser are prohibited, otherwise, the equipment may be damaged.
The high and low-temperature environmental chamber should be electrified regularly every month during the lengthy shutdown period, and the power-on time should be more than 1h.
Professional manufacturers of high and low-temperature environmental chamber insist on taking out the test samples after each test and wipe the workroom wall of the environmental chamber to keep the inner box clean.
Cleaning and balance of the circulating blade and condenser fan: Similar to that of the cleaning evaporator, because the working environment of the environmental chamber is different, a lot of small particles like dust will condense on the circulating blade and condenser fan. Hence, they should be cleaned regularly.
The power supply voltage of the high and low-temperature environmental chamber fluctuations, such as repeated power failure. In this case, it is suggested to suspend the use of high and low-temperature environmental chamber and close the power supply to prevent the burning of the compressor. Do not start the compressor immediately after the shutdown of the high and low-temperature environmental chamber. It should be stopped for 2-5 minutes before restarting.
The condenser of the high and low-temperature environmental chamber should be cleaned every three months. The condensing fan should be regularly overhauled and the condenser should be cleaned and dedusted so as to ensure its good ventilation and heat transfer performance.
High and low-temperature environmental chamber should be placed in a well-ventilated position with low humidity and smooth ground, 60 ~ 70 cm of use and maintenance space should be left around.
During the operation of high and low-temperature environmental chamber, the frequency of door opening should be minimized and the spillage of cold air should be reduced.
The usage details of high and low-temperature environmental chamber should be used by enterprise users in daily use.
관련 권장 사항
-
Operation method of reaction kettle for circulating heating device
1145The laboratory single-layer glass reactor equipped with the circulating heating device can place a flask containing the reaction solvent on the inner layer for stirring reaction, and the interlayer can realize constant temperature heating and cons...
세부 정보 보기 -
Vocs gas condensation recovery unit processing instructions
1376With the continuous inspection of environmental protection, Wuxi LNEYA VOCS gas condensation recovery device has also received continuous attention from the public. Most chemical, pharmaceutical and industrial industries are urgently dealing with ...
세부 정보 보기 -
Liquid-cooled battery pack AMS cooling system introduction
902The LNEYA liquid-cooled battery pack AMS cooling system can be applied in many scenarios in the new energy material industry. In the midstream industry of new energy raw materials, the purification of raw materials, the process temperature con...
세부 정보 보기 -
저온 냉각기는 금형 산업에 어떻게 적용됩니까?
1033아시다시피 저온 냉각기는 특히 금형 라인에서 널리 사용됩니다. 그렇다면 금형 산업에서 어떻게 작동하는지 모두 알고 계십니까? 모르는 경우 저와 함께 살펴 보겠습니다.저온 냉각기를 사용하여 모를 냉각 할 때 ...
세부 정보 보기