Pay attention to the installation of high and low temperature cooling circulator
The high and low temperature cooling circulators can only be operated better if they are installed correctly. If the installation is not in place during the installation process, the high and low temperature cooling circulators will have certain hidden dangers in operation. What are the hidden dangers?
When installing the high and low temperature cooling circulator, it is necessary to pay attention to the refrigerant pipe entering the dust impurities, which will cause the cooling effect of the high and low temperature cooling circulator to decrease, and increase the wear of the high and low temperature cooling circulator compressor, thereby causing the high and low temperature cooling circulator group to be generated. Blockage, affecting the cooling effect. For the refrigerant pipe, it is necessary to pay attention to the refrigerant pipe leakage problem. If the leakage problem occurs, the overall cooling effect of the high and low temperature cooling circulator will be reduced. During this period, the long-term overheating operation of the compressor is extremely easy to make the life of the high and low temperature cooling circulator decline.
When the high and low temperature cooling circulator is installed, if the line is installed incorrectly, it will accelerate the damage of the electrical components, and may even cause the unit to operate in a chaotic manner, so that the individual control or centralized control cannot be realized, and the high and low temperature cooling circulator system cannot operate.
Wuxi Guanya LNEYA high and low temperature cooling circulator will produce condensed water during the process of cooling. The smooth discharge of condensed water will affect the installation of high and low temperature cooling circulators. The condensate pipes will be taken out from the internal machine to the outside or to the floor drain. Maintain at least >1% slope. When the discharge of the condensate line of the high and low temperature cooling circulator is insufficient, the unit may leak water and cause a short circuit of the power supply.
When installing the high and low temperature cooling circulator, it is necessary to prevent the outside of the equipment from being blocked within 1 meter. All the landing feet must be equipped with shock absorbing blocks to ensure that the high and low temperature cooling circulators operate normally. If the high and low temperature cooling circulator is improperly installed, the airflow will be short-circuited, and the protection switch action caused by the short-circuit of the airflow will cause the noise of the high and low temperature cooling circulator to affect the surrounding environment.
Therefore, the installation of high and low temperature cooling circulators should be careful to avoid improper installation and avoid these faults, and strive to make the high and low temperature cooling circulators operate effectively.
Related recommendations
-
Application area of high temperature refrigeration and cooling control system
1942The high-temperature refrigeration and cooling control system is used for supporting glass reactors, rotary evaporators, fermentation tanks, and calorimeters; widely used in petroleum, chemical, metallurgical, biochemical, physics, testing and che...
View details -
Main points of maintenance of flash high and low temperature test chiller
2051Buyers of flash high and low temperature test chiller are increasing day by day. Many people find that the service life is greatly reduced after purchasing. Therefore, operation management and maintenance personnel must have certain professional k...
View details -
How important is the insulation of the chiller?
2617Answer: For the chiller, if it is operated at high temperature, a large amount of cold air in the industrial chiller may be severely lost. After the sealing effect of the use environment, through timely and effective heat preservation, the operati...
View details -
How does the cooling and heating circulator equipment control the temperature of the jacket glass re
1812The cooling and heating circulator equipment is often equipped with a reaction kettle for temperature control, so how to connect and control the temperature? 1. Circular jacket inlet and outlet interface We mainly use flange interfaces for the in...
View details