Explosion-proof hot and cold machine winter maintenance instructions

Industry News 소식 2782

When the explosion-proof type hot and cold integrated machine is used at the end of the day or when it is not used by the standby, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water in the pipe, and store it in a dry place to prevent freezing and expansion. Damage to machine parts (such as coolers, pumps, connecting copper pipes). The method of removing residual water is as follows:

1. The water sequence series needs to disconnect the cooling water and hot water inlet and outlet pipes and open the corresponding ball valve. Take the air gun to the hot water (outlet) inlet and let the residual medium inside the system discharge from the cooling water inlet (cooling) The water outlet is discharged from the inlet due to the electromagnetic valve. It is determined that there is no water in the pipeline and it can be stopped.

2. The standard explosion-proof type hot and cold integrated machine needs to disconnect the connecting pipe of the cooling water inlet and outlet, open the ball valve and let the machine be in a cooling state. When the cooling electromagnetic valve is opened, take the air gun and blow it into the cooling water inlet to make it from the water outlet. Discharge, determine that there is no water in the pipeline and then stop.

Kindly note, please be sure to disconnect the cooling water connection pipe when the equipment is not in use, and clean the remaining cooling water/heat transfer oil in the pipe, and store it in a dry place.

In the winter, when you do not need the explosion-proof type hot and cold machine, you need to pay attention to turn off the explosion-proof hot and cold machine and clean it as well, so as to avoid the residue affecting the performance of the explosion-proof hot and cold machine.

The prev: The next:

Related recommendations

  • Effect Of Humidity On Laboratory Chillers

    2012

    The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance...

    View details
  • Clean of Ultra-low Temperature Freezer

    1727

    Cleanenvironment of ultra-lowtemperature freezer: Once a month Clean up all ground debris and dust with sanitary ware, reduce dust adsorption in compressor and refrigeration system, affect heat dissipation Prevent dust from adsorbing on circuit bo...

    View details
  • Relevant knowledge of reactor refrigeration equipment

    2102

    The reactor refrigeration equipment is a kind of water cooling equipment, which is a kind of cooling water equipment that can provide constant temperature, constant flow and constant pressure. The working principle of the reactor refrigeration equ...

    View details
Expand more!