LNEYA high and low temperature heating refrigerator maintenance instructions
High and low temperature heating refrigerators use circulating water to replace circulating water regularly every month. If heat transfer oil is used, heat transfer oil should be replaced periodically every six months to one year. When the high and low temperature heating refrigerator is used for more than 150 degrees for a long time, check the heat transfer oil every three to six months, and decide whether to replace it according to the actual situation. When replacing the circulating oil, do not let water or foreign matter fall into the fuel tank.
Due to the thermal expansion and contraction during transportation and work in the middle of the machine, the nut of the terminal may be loosened, resulting in excessive current causing oxidation of the copper of the terminal, causing the short circuit to burn out the heating tube and the contactor. Maintenance of the heating tube of the high and low temperature heating chiller requires attention. Remove the sealing plate after the machine, open the wiring cover of the heating tube, and use the corresponding size of the sleeve for the nut of each connection and the nut at the joint of the copper piece (including under the copper piece). The nuts are all tightened and reinforced. If the water/oil scale of the high and low temperature heating refrigerator is serious, the whole heating pipe should be removed, and the surface of the heating pipe and the inside of the heating pipe should be cleaned and maintained to prevent the heating pipe from being burnt out due to poor circulation of the system.
When using the equipment, be sure to open the cooling water inlet and outlet valves on the back of the machine, with or without cooling water. The water circulation high and low temperature heating refrigerator may need to avoid the high pressure power failure of the machine due to thermal expansion during the heating process, and the pressure of the cooling water remaining inside the cooler may be prevented from being ruptured due to heat exchange expansion. Causes oil and water to mix and the machine does not work properly.
When not in use, be sure to disconnect the cooling water connection pipe, clean the remaining cooling water/heat transfer oil in the pipe, and store it in a dry place.
High and low temperature heating refrigerators need to be shut down for a period of time due to production. When restarting the machine, it is necessary to clean the filter and heating tube of the Y-type filter of the hot oil inlet to avoid the machine is not running for a long time, and the grease and impurities are deposited inside. The circulation is not smooth and the service life is shortened.
The maintenance of high and low temperature heating chillers is an important part of daily operation. Please keep in mind the high and low temperature heating chiller maintenance during the daily operation of the operator.
Related recommendations
-
Structural Characteristics of Industrial Recirculating Chiller
1836In the chemical reaction, there are strict requirements for the reaction temperature. It is necessary to raise the temperature to an appropriate temperature to carry out the chemical reaction smoothly. After the reaction, the temperature in the re...
View details -
Test instructions for refrigeration heating temperature control system for fuel oil test
2509The refrigeration heating temperature control system can be tested for different projects during operation. The detection of different projects is different. Among them, the refrigeration heating temperature control system for fuel oil testing is ...
View details -
What type of temperature control system is required for smear preparation in the pharmaceutical industry?
2015In the pharmaceutical industry, negative pressure drying and smear preparation have specific requirements for temperature control, and usually require precise and adjustable temperature control devices to ensure product quality and process stabili...
View details -
Chiller for 200L distillation kettle
1730The chiller for 200L distillation kettle needs to meet two main functions at the same time:One is to condense methanol vapor, and the other is to cool the material during the reaction process. In summary, the chiller supporting the 200L distillati...
View details
LNEYA Thermo Refrigeration Co.,Ltd