Low temperature freezer (explosion proof) product application instructions
LNEYA low temperature freezer (explosion proof) is mainly used for low temperature storage in chemical explosion areas. The equipment adopts microcomputer control, multiple safety protection and more reliable operation; single compressor automatic cascade supercooling refrigeration technology; the compressor adopts Secop and France Taikang brand, contactors and circuit breakers all adopt Schneider brand, which shows the high pressure of the refrigeration system. Low pressure; self-diagnosis function, freezer overload protection, high pressure switch, overload relay, thermal protection device and other safety guarantee functions, fully guarantee the safety of use; double seal, mold heat insulation layer, ultra-thick polyurethane foam insulation layer, thermal insulation performance Good; user-friendly design, flexible and convenient.
Multi-fault alarm (over-temperature alarm, sensor alarm, high-voltage alarm, compressor overheat alarm); power-on delay protection; air pressure balance hole ensures that the door can be opened smoothly and easily every time. Temperature recording function: record body temperature and set temperature. Alarm recording function: Independently record fault alarms.
Single-phase power supply 220V 50HZ (other specifications can be customized), aluminum alloy isolated explosion-proof motor, wind vane, compressor installed in fire cabinet, explosion-proof electrical cabinet, fire temperature sensor, pressure protector installed on fire cabinet, all components are Safety grounding, explosion-proof product installation license number: PCEC-2017-B025.
Related recommendations
-
Instructions for using the hydrogenation reactor cooling and heating integrated system
2475There are many accessories in the hydrogenation reactor cooling and heating integrated system, from the compressor to the electrical components. LNEYA reminds you that if you find more evaporator freezing oil, it is recommended to deal with it in ...
View details -
Destructive application effect of components in chip temperature measuring device
2217The components can be tested in high-temperature and low-temperature cold sources in the microfluidic chip temperature measuring device. The destructive analysis of components is also an important application, which can measure the design, structu...
View details -
High and low temperature device related instrument maintenance instructions
2074The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperatu...
View details -
Leakage Detection Tips of Low Temperature Freezer
2510Pressure leaking detection It is an effective way to check and find out the leakage point. The leakage detecting pressure of refrigerating system of freezer is relevant to the type of refrigerating fluid and cooling and the location of tube. The l...
View details