Performance and installation points of LNEYA ultra-low temperature refrigerator
LNEYA Ultra-Low Temp. Freezer is widely used in blood stations, hospitals, health, and epidemic prevention departments, research institutes, electronics industry, chemical medicine, biological engineering, laboratory, military industrial enterprises etc.
Refrigeration Using single compressor cascade technology, simple structure, low energy consumption, low failure rate; Refrigerant using single compressor cascade technology, simple structure, low energy consumption, low failure rate.Safety Protection; High and low pressure protection and display, Electric leakage protection, Power outage alarm, ambient temperature monitoring, sensor fault alarm,control system UPS power.
In order to achieve the long-term use of low-temperature freezer minus 30 DEG ~-86 DEG and prolong its life, we need to pay attention while using. Today LNEYA will tell something about it and hope them be helpful for you.
1. The indoor temperature should not be too high, it is better to put in the air-conditioned room. Always pay attention to the indoor voltage, keep it stable.
2. Reduce the times of opening the door. Once the sample is not too much. It is suggested that it should be put in batch and classified if the specimen is large.
3. Do not open the door to find things. Take the sample quickly and determinedly.
4. Regular defrosting is also essential.
5. According to the sample storage temperature demand, set the corresponding temperature. When the sample storage temperature needn’t to be-86 degrees.It is not recommended to set the temperature to -86 degrees because this makes the ultra-low temperature refrigerator tired and costly.
Related recommendations
-
Laboratory crystallization water chiller
1851Laboratory crystallization water chiller is a device specially used in laboratory environment to control the temperature conditions during crystallization. This equipment is mainly used in the research and development process of chemistr...
View details -
The Importance of Choosing a Quality Chiller Manufacturer
1669The first is professional operators.Professional refrigeration practitioners are the prerequisite for the maintenance, repair and maintenance of the chiller. If there are no professionals to work on the refrigeration equipment, it will not only c...
View details -
Precautions for changing the refrigerating oil in the cooling system of the car charger
1795The cooling system of the car charger should pay attention to the condition of the refrigerating oil during the operation. After the compressor is started, carefully observe the changes in the oil temperature and oil pressure. If the oil changes c...
View details -
Description of driver chip power supply in chip test temperature control system
1752The chip test temperature control system is mainly for the cold heat source test equipment for various drive chips. Before the operation of the Wuxi Guanya chip test temperature control system, the user needs to know the power of the drive chip. I...
View details