Parameters of small gas condensing liquefaction system
During the process of loading and unloading gasoline and refueling vehicles, and collecting high-concentration gas from the chemical plant. One or two methods in the process of adsorption or condensation, or the conversion of oil and gas from a gaseous state to a liquid state, and then into gasoline, to achieve recycling purposes. Oil and gas recovery is a high-tech energy-saving and environmentally-friendly technology. By improving the utilization rate of energy and reducing economic losses, it can obtain considerable benefits.
Wuxi Guanya LNEYA small gas condensing liquefaction system is used to cool the gas (non-corrosive) or condensate and recover as a non-corrosive gas.
The gas heat exchange system has a pressure resistance of 25 bar; the temperature range is from -40 ° C to -75 ° C, which can meet different temperatures; the internal use of environmentally friendly refrigerants; the use of secondary subcooling technology, rapid cooling, low temperature limit.
Imported brand semi-closed piston compressor, scroll flexible compressor, fully enclosed piston compressor, the main brands are Duling, Taikang, Emerson; the evaporator uses a casing heat exchanger, small size, long residence time, high efficiency ;
Use a full set of imported cold controls (DANFOSS pressure controller, balance valve, expansion valve, solenoid valve, dry filter, Emerson oil separator, ALCO sight glass, check valve, etc.);
The use of Danfoss expansion valve, Emerson electronic expansion valve, high temperature control accuracy;
It adopts Siemens PLCS7-200/300PLC and LNEYA touch screen display to carry out automatic control operation, and has temperature curve display, temperature record U disk, fault alarm record;
The whole machine is installed, the system has been tested in the factory, and the user only needs to install the refrigerant pipeline and the cooling water pipeline to complete the operation;
Factory test: Each refrigeration unit is tested at the factory with a load of not less than 12 hours.
Related recommendations
-
The difference between direct contact liquid cooling and cold plate liquid cooling technology
2614The cold plate liquid cooling technology is an implementation method in which the heat of the heating components is indirectly transferred to the cooling liquid enclosed in the circulating pipeline through the cold plate, and the heat is...
View details -
LNEYA low temperature chiller selection classification description
2592Different enterprises and different industries have different requirements for the low-temperature chiller of Wuxi Guanya (LNEYA). The choice of models is also different, so it is better to understand them in the selection. The low temperature chi...
View details -
What should you pay attention to when using the cooling and heating oil bath?
1840In the high and low temperature control, cooling and heating oil bath is one of the more important equipment. What aspects do users need to pay attention to when running the device? The cooling and heating oil bath equipment should be kept clean a...
View details -
Cooling and heating temperature control equipment for liquid distribution system
1748The cooling and heating temperature control equipment of the liquid distribution system is a dynamic temperature control system produced by LNEYA. When we purchase the cooling and heating temperature control system of the liquid distribution s...
View details
LNEYA Thermo Refrigeration Co.,Ltd












