Heat transfer oil for cooling and heating temperature control systems in the chemical and pharmaceut
The cooling and heating temperature control system, also known as a high and low temperature circulator or dynamic temperature control system, is a temperature control equipment used in the pharmaceutical and chemical industry to provide cold and heat sources for supporting reaction kettles. The LNEYA cooling and heating temperature control system uses heat transfer oil as the heat transfer medium. Depending on the temperature range and model of the equipment, different types of heat transfer oil can be selected.
1. Application note: Heat transfer oil is divided into different models based on different temperature ranges. It is recommended to choose the appropriate heat transfer oil according to the temperature range of the equipment model. Due to differences in equipment configuration, the heat transfer oil consumption of different refrigeration heating and temperature control thermostats varies. If it is a fully enclosed circulation pipeline, there is no water vapor or oil mist, and the amount used will be less than that of an open refrigeration heating and temperature control thermostat.
2. Quality analysis of heat transfer oil: The heat transfer oil in the cooling and heating temperature control system is generally analyzed from four aspects: viscosity, flash point, acid value, and residual carbon. Generally speaking, if the quality of the heat transfer oil in the refrigeration and heating temperature control thermostat changes, its viscosity will change. A change in acid value indicates that the heat transfer oil is contaminated or oxidized, and operators need to pay attention to it and replace it in a timely manner. If the heat transfer oil does not corrode, check the residual carbon value. Once it reaches the average value, it should be taken seriously. If these four data items do not exceed the range of changes, it indicates that the quality of the heat transfer oil in the refrigeration heating temperature control thermostat is good and can still operate normally. If one item is abnormal, it is necessary to consider taking corresponding measures and replacing it with a new heat transfer oil in a timely manner.
3. Precautions for use: The placement environment of heat transfer oil and refrigeration heating temperature control thermostats should be in a well ventilated and reliable environment. Although the boiling point of heat transfer oil is high, it is still necessary to avoid open flames. If the heat transfer oil leaks, it can cause accidents in contact with open flames, so open flames should be kept away. At the same time, it is necessary to be careful not to place it in the hot gas flame area to avoid ignition sources.
Related recommendations
-
What are the common connection methods for industrial chillers?
2067There are several connection methods for industrial chillers, which are suitable for pipe connection under different conditions. First, welding connectionWelding is the most important and widely used connection method in pipeline engineering. Weld...
View details -
Influence of Freezing Oil on New Energy Vehicle Drive Motor Test System
2494The hazard of the refrigerating oil in the new energy vehicle drive motor test system increases the condensation temperature and the condensing pressure; the condenser heat transfer deteriorates. Because the oil film produced by the oil entering t...
View details -
What are the effects of the oil separator on the equipment analyzed by the chiller manufacturer
1966Oil separators use more accessories in thechiller refrigeration system. So as users, we need to understand where the mainimpact is in order to better use the equipment.In the configuration of the chiller, theposition of the oil separator is aft...
View details -
How to deal with the equipment failure alarm of the recirculation chiller
1978What to do if there is a failure and alarmduring the use of the recirculating chiller equipment? In order to ensureproduction, such problems need to be resolved quickly. We must first understand the causes offailures and alarms, and adopt dif...
View details
LNEYA Thermo Refrigeration Co.,Ltd












