High precision semiconductor incubator maintenance instructions
The high-precision semiconductor incubator is in the state of the evaporator as a gas refrigerant; after the adiabatic shrinkage of the shrinking machine, it becomes a high-temperature and high-pressure state, and the contracted gas refrigerant is condensed in the condenser by equal pressure, and is converted by condensation. The liquid refrigerant is expanded into a low pressure through a throttle valve to become a gas-liquid mixture. The liquid refrigerant at low temperature and low pressure absorbs the heat of the cold material in the evaporator, and changes from the head to the gaseous refrigerant. The gaseous refrigerant enters the shrinking machine through the pipe and starts the new cycle. This is the high-precision semiconductor thermostat reincarnation. Four processes.
The high-precision semiconductor thermostat sealing part is nursed back. Since the assembled high-precision semiconductor thermostat is made up of several pieces of insulation board, there is a necessary gap between the boards. In the construction, such gaps are sealed with sealant, in order to avoid air. And the water comes in, so in the use of some parts of the seal is not repaired in real time.
High-precision semiconductor incubator ground nursed back, usually the surface of the small-assembled high-precision semiconductor incubator uses thermal insulation board. When using high-precision semiconductor incubator, in order to avoid a large amount of ice and water on the ground, if there is ice, it must not be processed. Use hard objects to knock and damage the ground.
High-precision semiconductor incubators are used after assembly or long-term deactivation. The rate of cooling should be appropriate: daily operation at 8-10 °C is appropriate, and should be retained for a period of time at 0 °C.
High-precision semiconductor thermostat library board nursery, pay attention to the use should pay attention to the collision and scratching of the hard object on the library, in view of the possibility of becoming the concave and rust of the library board, it will seriously reduce the surface insulation function of the library.
The maintenance of high-precision semiconductor incubators is inseparable from the careful operation of our operators, so we should be kind to our equipment in daily operations, not too rough.
Related recommendations
-
How to Carry On Industrial Low Temperature Chillerstest Of Choosing The Better Company?
2080No matter what chillers are used, we need to constantly learn about the relevant knowledge of the industrial-low temperature chillers. Which company's low - temperature chiller is better? Let me tell you, in order to help you to use the industrial...
View details -
With these points, the use efficiency of the ultra-low temperature chiller can be more efficient
2093The structure of the ultra-low temperature chiller is more complicated. Its main function is to provide cold air to the product, which is the refrigeration function. If you want to improve the efficiency of the freezer, you must pay attention to t...
View details -
60P ultra-low temperature water chiller consumes too much energy and needs attention
189760p ultra-low temperature water chillers of different manufacturers have different performance configurations and different energy consumption. If you find that the energy consumption is too large, you must check in time to see if there is a probl...
View details -
Debugging steps of industrial water chiller in chemical industry
2109After completing the installation ofindustrial water chillers in chemical enterprises, certain debugging needs tobe carried out in the early stage ofoperation. Only through careful debugging can we find out whether there arehidden troubles in...
View details
LNEYA Thermo Refrigeration Co.,Ltd