Application Of Compressor In Low Temperature Chiller
Compressor is an important part of cryogenic refrigeration industry. As far as low temperature chiller is concerned, different brands and types need to be selected when buying compressors. Therefore, when choosing cryogenic refrigeration compressors, we should pay attention to the advantages and disadvantages of each compressor and make better choices.
The cryogenic refrigeration compressors mainly include semi-enclosed piston refrigeration compressor, rotor refrigeration compressor, screw refrigeration compressor, centrifugal refrigeration compressor and so on. The advantages and disadvantages of these cryogenic refrigeration compressors should be dialectically analyzed, and the compressor should be better used and selected.
Semi-hermetic piston refrigeration compressor is widely used in low temperature chiller. The refrigeration equipment of semi-hermetic piston refrigeration compressor has simple internal structure, low requirements for processing materials and processing technology. Compared with other compressors, semi-hermetic piston refrigeration compressor has strong adaptability, wide pressure range and semi-hermetic. The closed piston refrigeration compressor system is relatively simple, and it can meet a wide range of pressure and refrigeration capacity. But at the same time, the semi-closed piston refrigeration compressor also has some defects, such as the shape is larger and the volume is heavier, and has greater noise and vibration. It is difficult for semi-closed piston refrigeration compressor achieve high speed. It has many problems such as vulnerable parts, and inconvenient maintenance.
Rotor refrigeration compressor of low temperature chiller is fully enclosed. Small refrigeration equipment is used more, and its refrigeration capacity is not very prominent. Compared with other compressors, it has simple structure, small size, light weight, no suction valve, high speed, small vibration and smooth operation. At the same time, compared with other compressors, the rotor refrigeration compressor system requires higher cleanliness and processing accuracy. The leakage, friction and wear between slider and cylinder wall are larger, and the performance of the compressor decreases obviously. This is also something you need to realize. The other three devices are shown on other pages of our company.
Related recommendations
-
How to maintain and extend the service life of the dynamic temperature control system?
1893Dynamic temperature control system is a fully enclosed refrigeration and heating temperature control device that provides cold and heat sources. The service life is related to the usual maintenance and cleaning. Dynamic temperature control system...
View details -
What are the common connection methods for industrial chillers?
2090There are several connection methods for industrial chillers, which are suitable for pipe connection under different conditions. First, welding connectionWelding is the most important and widely used connection method in pipeline engineering. Weld...
View details -
Maintenance of the condenser of high and low temperature circulation device
2598The condenser in the high and low temperature constant temperature circulation device is one of the accessories in the refrigeration process, and its performance is very important. LNEYA reminds the user that regular maintenance is required after ...
View details -
Why do constant temperature and humidity chamber need water cooling units?
1813Constant temperature and humidity chamber need water cooling units mainly for the following key reasons: Accurate temperature and humidity control: Water cooling units can provide efficient and accurate temperature regulation capabilities, which i...
View details
LNEYA Thermo Refrigeration Co.,Ltd












