How To Choose the Ultra Low Temperature Recirculating Chiller Expansion Valve?
Selection and installation of the expansion valve for ultra low temperature recirculating chillers: the selection of expansion valve plays an important role in the performance of the ultra low temperature recirculating chiller refrigeration system. The correct choice of expansion valve will maximize the use of the evaporator and make the evaporator always be matched to the heat load.
First, the selection of thermal expansion valve.
In the ultra low temperature recirculating chiller refrigeration system, the selection and installation of the expansion valve is very important. Only the correct selection and installation can ensure the normal operation of the unit. Therefore, when selecting the expansion valve, we can use the appropriate size of the thermal expansion valve according to the size of the evaporator load and the evaporating temperature. The capacity of the commonly used expansion valve is about 20% larger than the evaporator heat load. For small chiller refrigeration systems, gas-filled thermal expansion valves are generally used, and medium-sized ultra-low temperature circulating chiller refrigeration systems mostly use adsorption-filled or mixed-filled expansion valves.
Second, the expansion valve installation.
1. The chiller expansion valve is installed in front of the evaporator and is usually installed in a vertical position. Considering the ease of installation and maintenance, the cooling loss is small and should be as close as possible to the inlet of the evaporator.
2. The working condition of the expansion valve for the ultra low temperature recirculating chiller has a direct relationship with the installation position of the temperature sensing package. Because the expansion valve completely adjusts the opening size of the expansion valve by the temperature change of the temperature sensing package. The temperature sensor package is installed on the pipe at the outlet of the chiller evaporator. As the evaporator outlet pipe grows, its superheat gradually increases. Therefore, the position of the expansion valve temperature sensing package is directly related to the amount of fluid supplied from the expansion valve.
Related recommendations
-
2019 CPHl China | LNEYA W5P22 Exhibition Site&Wonderful
2062From June 18th to June 20th, 2019, the 19th World Pharmaceutical Raw Materials China Exhibition - CPhI China 2019 was held at the Shanghai New International Expo Center. LNEYA took a variety of equipment to the W5P22 booth, which lasted for three ...
View details -
Effect of cooling and heating system on glass reactor
2206The glass reactor is compact in volume and clear in structure, and can be conveniently operated in series and parallel in a flexible manner, fully satisfying various process occasions; the reaction path does not have any metal contact, and the inl...
View details -
-
Introduction To The Preparation Of Low Temperature Chiller’ Operation
2315Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently. Before running the low temperatu...
View details
LNEYA Thermo Refrigeration Co.,Ltd