Integrated control system high and low temperature cycle device ZLF series use items
With the development of society, the chemical industry has been further developed, and the temperature system control of the reactor has been strengthened, so as to ensure that the monitoring environment is in a good state, to ensure that the temperature condition is debugged in real time through the man-machine interface, and that the production process meets relevant requirements . Based on this, Wuxi Guanya launched the high and low temperature cycle device.
The reactor is used in the process of chemical production. The equipment has its own characteristics. The entire chemical reaction is complex, and the reaction mechanism is also complicated. It is also affected by many factors, mainly the type of catalyst, external conditions, Changes in the amount of raw materials added will directly affect the normal operation of the system. During the chemical reaction, because some methods are more complicated, mainly in terms of conversion rate, in order to ensure the quality, it is very important to strengthen the control of the reaction temperature.
As far as the current situation is concerned, the temperature control of the reactor is mainly affected by the process system of chemical reaction. Therefore, in order to better control the temperature of the reactor, you need to be familiar with the relevant process system. However, because the temperature control of the high and low temperature cycle device is more complicated, it needs to be carried out in the following aspects in practical applications:
① Control the heating system to ensure that the reaction temperature is at a constant state.
② Effectively control the shape and structure of the kettle, and at the same time, ensure the tightness of the entire process and ensure product quality.
③ Focus on strengthening pressure control to ensure that the entire reaction process is adequate to prevent dangerous situations.
④Ensure that the entire automation control system is more economical and reliable, and that the temperature is within the normal range, which can effectively reduce the reaction time.
Difficulties in control As far as the current situation is concerned, there are still many difficulties in controlling the reactor, mainly in the following aspects:
1. During the chemical reaction, a series of changes will occur in the heating system, and the whole process and its susceptibility to the external environment, coupled with the obvious difference in the change trend during the reaction, will make the reaction kettle become A non-linear system.
2. The characteristics of the high and low temperature circulation device reactor are that the volume and heat capacity are very large, and endothermic and exothermic reactions can occur at any time. Therefore, the entire process time will be longer when collecting.
3. When the polymerization reaction occurs in the reactor, the chemical raw materials are changing, which will cause changes in the process and materials, and a series of endothermic and exothermic reactions will occur. Therefore, it is very complicated for the chemical production itself. .
4. In chemical production, the reaction will be exothermic, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause “poly explosion”. If too much waste heat is released, the overall stability will decline, and the product quality will be affected. Therefore, it is very important to control the reaction temperature.
The stirrer used in the reaction kettle of the high and low temperature circulation device has requirements on the rotation speed. The motor is mainly adapted to the agitation of the reducer for the entire movement process. For vertical installation of the reducer, it is necessary to ensure that the lubrication is in a good condition, without vibration and leakage, and always in a normal operating state. This requires the strengthening of daily maintenance control. The reducer will vibrate during the rotation. The main reason is the following aspects, which need to be adjusted in time for these aspects.
Reaction kettle supporting high and low temperature circulation device
(1) When the reactor is in operation, it must be carried out in strict accordance with relevant standards to prevent over-temperature and over-pressure.
(2) strictly control the temperature according to requirements.
Related recommendations
-
Chiller for 200L distillation kettle
1730The chiller for 200L distillation kettle needs to meet two main functions at the same time:One is to condense methanol vapor, and the other is to cool the material during the reaction process. In summary, the chiller supporting the 200L distillati...
View details -
The relationship between vocs adsorption condensing equipment price and configuration
1942The quality of vocs adsorption condensing equipment must be guaranteed. This can be used with confidence. The reason for the power consumption may also be that the gas inhaled by the BITZER compressor allows a certain degree of superheat, but the ...
View details -
Integrated temperature control unit for reactors in pharmaceutical production
1880The reactor system can effectively cooperate with the integrated temperature control system to meet the temperature control requirements of different chemical reactions and production processes. The reactor temperature control equipment in the pha...
View details -
LNEYA hot and cold machine SUNDI manual
2697The temperature range of the hot and cold machine ranges from -120 ° C to 350 ° C. It has superior performance and unique performance. It has high precision and intelligent temperature control. The high cooling power is from 0.5 to 1200 kW. High p...
View details
LNEYA Thermo Refrigeration Co.,Ltd