Attention points for daily inspection of low temperature control equipment at minus 30℃
The low temperature control equipment at minus 30 degrees Celsius is a refrigeration unit or also called a refrigeration unit. The difference from the chiller is the temperature range. It is a commonly used low-temperature equipment in the industry and needs to operate for a long time. So what points should be paid attention to in daily inspection during operation?
1. Power supply part inspection
Before installation, the low temperature control equipment of minus 30 degrees Celsius will make a plan for the surrounding installation environment, circuit and power supply. If the conditions and standards are suitable, the installation will be carried out, and the installation will be re-planned if the conditions are not suitable. After a long period of use, check the power supply part to see if the power supply accessories are damaged, whether the wires inside and outside the equipment are aging, and whether there is damage. If there are problems, check and correct them in time.
2. Refrigerant inspection
The refrigeration effect in the low temperature control equipment of minus 30 degrees Celsius is a more critical part. If the refrigerant leaks, it will affect the refrigeration temperature, fail to achieve the expected refrigeration effect, and affect the overall work progress. While checking the refrigerant of the low temperature control equipment at minus 30 degrees Celsius, check whether the joints of the relevant parts are loose or cracked. If there is a problem, solve it quickly to avoid refrigerant leakage. If a refrigerant leak is found, it needs to be supplemented, and it needs to be added in accordance with relevant standards.
3. Pipeline inspection
The low temperature control equipment of minus 30 degrees Celsius needs to be inspected after a certain period of time to see if there is any leakage. If a leak is found, it needs to be repaired, and then used after checking that there is no leakage.
Related recommendations
-
Good news! Wuxi Guanya LNEYA Refrigeration gets a new name
4439According to the `` Notice on Publishing the Evaluation Results of Unicorn and Gazelle Enterprises in the 2019 South Jiangsu National Independent Innovation Demonstration Zone '' issued by Jiangsu Sunan National Independent Innovation Demonstratio...
View details -
Description of pump selection in steam-saturated system temperature control unit
2112The steaming system temperature control unit is one of the more used equipment in the pharmaceutical chemical industry. The performance of the LNEYA steaming system temperature control unit depends on the design of the whole system and the specifi...
View details -
The importance of chiller compressors
2127In the operation of the precision chiller, the compressor is a more important part. If we want to understand the chiller, we have to understand the compressor. Most precision chiller compressors have a thermal switch inside. The function of this s...
View details -
Explosion Proof Refrigerator-Suitable for mechanical producing plant
2905LNEYA Explosion Proof Refrigerator is a kind of special refrigerator mainly used for the special industrial environment to keep dangerous goods which are difficult to preserve, volatile and inflammable and explosive. With the development of petrol...
View details