선형 급격한 온도 변화 테스터 비우기 및 채우기 지침
Before starting the linear rapid temperature change tester, check whether the relevant protective measures are in place, such as fire protection, protection, leak prevention and other tools. Check whether the power supply is in place according to the power supply installation and equipment grounding, whether the phase sequence is correct, and whether the grounding is good. Then power on the equipment, and then check whether the relevant valve is open. Otherwise, the circulating pump will be blocked and burned out, or the pipeline pressure will be too large to crack the pipeline.
The linear rapid temperature change tester drains the liquid, and the liquid addition and emptying are performed simultaneously. The linear rapid temperature change tester device is located at the upper end of the device, closed clockwise, and opened counterclockwise. The linear rapid temperature change tester exhaust valve is located on the side of the unit. Use the auxiliary tool to insert a hole, turn it clockwise, and open it counterclockwise.
The linear rapid temperature change tester can cause damage to the circulation pump if it is not filled with the circulating heat transfer medium in accordance with the following simple operation guide. The linear rapid temperature change tester needs to pay attention to the necessary protective measures, wearing rubber gloves, goggles, eye wash, etc., to ensure that the thermal medium meets the system requirements (temperature range, viscosity, corrosion, toxicity). Check the medium to ensure no precipitation, no color, no corrosiveness. If a small amount of sediment should be settled stably, the precipitate should not be added to the system when a heat transfer medium is added. The linear rapid temperature change tester should be splashed when dumping, and always pay attention to the sight glass on the side of the device to prevent the overflow into the electrical cabinet and damage the equipment and form pollution. Before adding the liquid, check whether the relevant pipeline is completely open. Whether the liquid port is closed.

If the linear rapid temperature change tester mixes different types of thermal fluid in the thermal fluid circulation, the linear rapid temperature change tester will be damaged. Different types of thermal fluids (eg mineral oil, silicone oil, synthetic oil, water, etc.) cannot mix with each other in the thermal fluid circulation. When replacing other types of thermal fluid, the thermal fluid circulation must be flushed. The previous thermal fluid is not allowed to remain in the thermal fluid circulation.
The linear fast temperature change tester’s emptying liquid is as shown above. After the process of emptying and adding liquid, the power can be turned on and the linear rapid temperature change tester can operate normally.
관련 권장 사항
-
How to Solve the Problem that Water 10hp Refrigerator Can’t Produce Water
1124Wuxi guanya has cold plate freezer for sale for the industrial cold treatment.Well,how to solve the problem of water outlet fault of 10hp cold plate freezer?Therefore,I have sorted out the relevant solutions for the water outlet fault of 10hp cold...
세부 정보 보기 -
2018 CIPM China | You have an invitation to the exhibition from LNEYA
1267The 56th (Fall 2018) National Pharmaceutical Machinery and China International Pharmaceutical Machinery Expo will be held from November 5th to November 7th, 2018 at Wuhan International Expo Center. As one of the professional communication platfor...
세부 정보 보기 -
How does the cooling and heating system achieve simultaneous temperature control?
1059Temperature control system The thermostat has heating and cooling functions, and can use the same medium for continuous temperature control from -120℃~320℃. The heating and cooling system of cooling and heating system is mainly composed of four pa...
세부 정보 보기 -
신에너지 자동차 모터 종합 테스트 시스템
1180LNEYA 신에너지 자동차 모터 통합 테스트 시스템을 실행할 때 제어판 설정이 필요합니다. 설정시 사용자가 사용 방법을 모르는 경우 설명서를 확인하여 사용할 수 있습니다. 새로운 에너지의 지표 ...
세부 정보 보기