저온 냉각기 작동 준비 소개
Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently.
Before running the 저온 냉각기, we need to check the refrigerant, water and electrical equipment, and check the oil separator liquid level, the correct oil position should be in the oil mirror center line between the line.
Be careful to check that all the pressure gauges for the low temperature chiller are open, and whether the oil thermometer has been inserted with the lubricating oil, and check or open all the valves on the oil road that they should be completely open.
Push the start button, the low temperature chiller starts, and then wait to see whether the oil pump is turning correctly, the oil pressure difference is not low than the surface pressure of 0.05-0.3Mpa, and the pressure difference of the oil filter does not exceed 0.1Mpa. Turn the coupling and operate the energy control valve at the same time, so that the unloading indication goes from 0%–100%, then 100%–0%, then manually stop the oil pump.
Try low temperature chiller with hand disc compressor coupling, no card resistance phenomenon shows the normal state. Open the exhaust valve on the compressor, water supply to the oil cooler, and water temperature depends on the oil temperature (the nozzle oil temperature is better to be 40 –55 c). At the same time, water supply to the condenser and evaporator , finally cover the main motor power supply, and the power lamp is on, then the low temperature chiller can be used normally.
With these detailed preparations, it is certain that the low temperature chiller can be better used to achieve the lowest cost and maximum operational efficiency.
관련 권장 사항
-
Three integrated thermal shock test chamber cooling method
1300The three integrated thermal shock test chambers are designed and manufactured according to user requirements. They are suitable for high and low temperature impact tests of high-temperature or low-temperature environments and for high-temperature...
세부 정보 보기 -
응축 처리를 위한 유기 폐가스를 선택하는 방법은 무엇인가요?
1303유기 폐기물 가스 장비의 응축 처리는 현재 환경 보호 요구 사항의 환경에서 사용되며, 응축 처리를 위해 유기 폐기물 가스 장비를 선택하는 방법, 효율적이고 효율적인 장비를 선택하는 방법 ...
세부 정보 보기 -
공정 엔지니어링에서 동적 온도 제어 시스템의 온도 제어
949화학 산업, 특히 공정 엔지니어링에서는 많은 공정이 온도에 묶여 있거나 특정 온도 제어 애플리케이션에 의해 지원될 수 있으므로 효율성이 높아집니다. 후자의 예로는 연속 온도 제어가 있습니다.
세부 정보 보기 -
배터리별 온도 사이클 테스트 챔버 냉각기 팁
1073경제의 급속한 발전과 함께 신에너지 자동차 산업도 급속한 발전을 이루었으며 배터리 산업의 요구 사항도 점점 더 높아지고 있습니다. 관련 산업에 적응하기 위해 LNEYA는 ...
세부 정보 보기