Compressor and system matching should be matched reasonably
When the compressor of cryogenic refrigeration system is replaced, the large size of the compressor does not represent goodness, and the matching between the compressor and the system should be reasonable. When the amount of condenser, evaporator, capillary and refrigerant is added in a fixed number, the compressor will be heated if the compressor changed to a larger size, and the service life will not be very long. Similarly, if the compressor changed to a smaller size, the refrigeration effect will not be very good.
Welding Requires Technology
When there is trouble in the cryogenic refrigeration system, the welding technology plays a key role in refrigeration maintenance, so the temperature is very important. On the weld joint of compressor in cryogenic refrigeration system, these pipes are often thicker and require large temperature. Therefore, some experience and skills are needed for welders.
Many users use copper tubes in pipe selection. The people working in the industry said that this kind of tube used in cryogenic refrigeration system is indeed corrosion-resistant, and the wall is thick enough, but after many tests, it shows that the iron tube of the cryogenic refrigeration system disc is more obvious than copper tube frost. It can be seen that copper pipe has good heat dissipation performance, but the heat preservation is not good when used in evaporator, so the copper pipe frosting does not seem to have the more ideal effect than the iron pipe.
Hotter the condenser is, the better the effect is.
Heat dissipation of the condenser in cryogenic refrigeration system is very important. Some users believe that the hotter the condenser is, the better the outside is, the cooler the inside is. The people working in the industry pointed out that this understanding is actually wrong, for condenser overheating is a phenomenon of poor heat dissipation, which should be used with caution.
Generally speaking, there are some differences between the system of the cryogenic refrigeration system and the technology of the ordinary double compressor refrigeration. When the cryogenic refrigeration system meets the above-mentioned faults, the operators should analyze the faults according to the specific question. If it can not be solved, then you can find the help of maintenance personnel to maintain the operation of the cryogenic refrigeration system scientifically.
관련 권장 사항
-
Vocs 흡착 장비 냉장 온도 제어 지침
1133환경 보호 요구 사항이 지속적으로 개선됨에 따라 각 공장은 생산 과정에서 발생하는 vocs 가스 처리에도 집중하고 있습니다. LNEYA 보컬 흡착 장비는 다양한 보컬 가스를 처리 할 수 있습니다. 그래서 당신은 얼마나 알고 있습니까?
세부 정보 보기 -
LNEYA 냉각 가열 시스템의 진공로 냉각 시스템 존재 여부
1125고온 진공로는 진공에 가까운 상태에서 전기 발열체에 의해 가열되는 산업용 용광로를 말합니다. 고온 진공로는 일반적으로 퍼니스, 전기 가열 장치, 진공 시스템, 밀폐형 퍼니스로 구성됩니다.
세부 정보 보기 -
Temperature description of glycol chiller
1062For users and friends, it is necessary tohave a deep understanding of glycol chillers before use. It is recommended toknow the temperature in various equipment such as refrigeration system,evaporating temperature, condensing temperature, etc.If...
세부 정보 보기 -
휠 모터로 구동되는 냉각 시스템의 물 차단 문제 해결 방법
1055냉각 시스템을 구동하기 위해 휠 모터를 장기간 사용하면 모든 종류의 고장이 발생할 수 있습니다. 휠 측면 모터 구동 냉각 시스템의 경우 물 차단 문제가 있는 경우 매우 위험하므로 적시에 효과적으로 처리해야 합니다.
세부 정보 보기