How to maintain the lubrication system of water-cooled chillers
Medium-sized water cooled chiller,
refrigeration temperature range from -80 ℃~ -30℃, safe,
reliable, rapid cooling for the liquid, widely used in petrochemical, medical,
pharmaceutical, biochemical and freeze-dried, military and other high-tech industries.
When the water cooled chiller is below 80℃ ~ 30℃ below zero
in the running system, people pay more attention to refrigerator, frozen water
cycle system and electric control system, so the lubrication system is often
overlooked. However, this system is also very important to the water cooled
chiller. The maintenance of the water cooled chiller is indispensable, now we
are going to tell you something about it.
1. Observe the normal oil surface, oil
temperature and oil pressure in the daily inspection.
2. Regularly check the oil quality
according to the oil change index stipulated in the frozen lubricating oil, and
replace or supplement the filtered new oil.
3. Pay attention to check and adjust the
end face clearance of the oil pump in the middle and overhaul, and replace the
pump when necessary. The end face clearance of the pump varies from 0.03 to
0.08mm. Please refer to the assembly technical requirements and factory
regulations of the pump for concrete value.
4. Regularly replace or clean the filter
core, pipeline, and crankcase.
The maintenance of the lubrication system
of the water cooled chiller requires techniques, which mainly involves the
performance of the compressor’s main engine. It is recommended to be operated
by professionals to avoid unnecessary losses.
If you are purchasing our LNEYA
water-cooled chiller, you can contact our after-sales team. If you have
purchase needs or questions in this regard, you can also contact our team
sales@lneya.com, we will reply to you as soon as possible.
Related recommendations
-
Troubleshooting of Common Faults of Industrial Water Chiller
2828As we all know, with the rapid development of modern industrial technology, in order to improve production efficiency, improve product quality and reduce consumption costs, the demand for temperature control equipment in the process is higher and ...
View details -
How to maintain and extend the service life of the dynamic temperature control system?
1913Dynamic temperature control system is a fully enclosed refrigeration and heating temperature control device that provides cold and heat sources. The service life is related to the usual maintenance and cleaning. Dynamic temperature control system...
View details -
Analysis of the characteristics of LNEYA precision chillers
2124Now, in many industrial productions, industrial chillers are needed to achieve the purpose of refrigeration in production operations. This shows that chillers play a very important role in various industrial production. The precision chiller uses ...
View details -
Instructions for the use of temperature control equipment for isolation reactors
1804The reaction kettle is a commonly used reactor in pharmaceutical and chemical production. The temperature control equipment of the isolated reaction kettle is realized by controlling two doors, namely the heating water valve and the cooling water ...
View details
LNEYA Thermo Refrigeration Co.,Ltd