Energy-efficient high and low temperature circulation box description
With the efficient development of the pharmaceutical and chemical industry, environmental pollution is also the subject of more attention. To this end, LNEYA actively responds to environmental protection, produces energy-efficient and high-temperature circulating boxes, and saves enterprise costs as much as possible.
The high and low temperature circulation box group reduces the condensation temperature under the premise of evaporation temperature. In order to meet the safety and production requirements of the equipment, the evaporation temperature is lowered to reduce the condensation temperature, so as to ensure the cooling water efficiency and increase the transformation. Adjust the reasonable operation of the chiller equipment. When the equipment is safely operated, the cooling unit operates at 70%-80% load ratio and runs at 100% load, and the power consumption per unit of cooling capacity is smaller. In this way, it is necessary to combine the operation of the water pump and the cooling tower.
Prevent and reduce pipe fouling to improve the heat exchange efficiency of the condenser and evaporator. Replenish water If the water treatment is not good, calcium carbonate and magnesium carbonate produced by the heating of calcium bicarbonate and magnesium bicarbonate will deposit on the pipeline. Decreasing the thermal conductivity, affecting the heat exchange efficiency of the condenser and the evaporator, and greatly increasing the electricity cost of the equipment. In addition to the water treatment technology, it is also possible to use the pipeline automatic cleaning equipment for pipeline cleaning. The high-low temperature cycle box group refrigerator frequency conversion device adjusts the speed of the centrifugal refrigerator compressor. After the low-pressure refrigerant passes through the centrifuge, the pressure rises. The higher the speed of the centrifuge, the higher the pressure rises. In actual operation, most of the equipment is running at a non-full load. A fixed-speed centrifuge wastes energy when the equipment is running at a small load. The variable frequency centrifugal chiller can automatically adjust the compressor speed according to the change of the load, and the energy saving space is relatively large.
These operating instructions can help the high and low temperature circulation box to be more energy efficient and use as much energy consumption as possible.
Related recommendations
-
Reactor heating hot cooling system instructions
2144The reaction heating and cooling system of the reaction kettle realizes the material reaction equipment during the reaction process of the material. The heating and cooling system of the LNEYA reaction kettle needs to pay attention to the reaction...
View details -
Ways to make ultra-low temperature circulating chillers more energy-efficient
1646In modern times, environmental protection and energy saving is the development theme, so is the industrial chiller. Then, how to improve your industrial chiller to be more energy conservation? First, to prevent and reduce the pipe scaling of u...
View details -
How to improve the efficiency of water cooled chillers?
2513Water cooled chiller is a kind of mechanical equipment that uses water resources for refrigeration. In recent years, water-cooled chiller is more and more widely used at home and abroad, mainly because most modern industrial production needs to us...
View details -
The Screw Chiller Factory With Noise Should Be Checked And Repaired In Time
1909Before we use an industrial screw chiller factory, we will check all aspects of it, such as parts inspection, configuration, noise, and so on. What should I do if there is noise in the screw chiller during use? Do I need someone to repair it? The ...
View details