Energy-efficient high and low temperature circulation box description
With the efficient development of the pharmaceutical and chemical industry, environmental pollution is also the subject of more attention. To this end, LNEYA actively responds to environmental protection, produces energy-efficient and high-temperature circulating boxes, and saves enterprise costs as much as possible.
The high and low temperature circulation box group reduces the condensation temperature under the premise of evaporation temperature. In order to meet the safety and production requirements of the equipment, the evaporation temperature is lowered to reduce the condensation temperature, so as to ensure the cooling water efficiency and increase the transformation. Adjust the reasonable operation of the chiller equipment. When the equipment is safely operated, the cooling unit operates at 70%-80% load ratio and runs at 100% load, and the power consumption per unit of cooling capacity is smaller. In this way, it is necessary to combine the operation of the water pump and the cooling tower.
Prevent and reduce pipe fouling to improve the heat exchange efficiency of the condenser and evaporator. Replenish water If the water treatment is not good, calcium carbonate and magnesium carbonate produced by the heating of calcium bicarbonate and magnesium bicarbonate will deposit on the pipeline. Decreasing the thermal conductivity, affecting the heat exchange efficiency of the condenser and the evaporator, and greatly increasing the electricity cost of the equipment. In addition to the water treatment technology, it is also possible to use the pipeline automatic cleaning equipment for pipeline cleaning. The high-low temperature cycle box group refrigerator frequency conversion device adjusts the speed of the centrifugal refrigerator compressor. After the low-pressure refrigerant passes through the centrifuge, the pressure rises. The higher the speed of the centrifuge, the higher the pressure rises. In actual operation, most of the equipment is running at a non-full load. A fixed-speed centrifuge wastes energy when the equipment is running at a small load. The variable frequency centrifugal chiller can automatically adjust the compressor speed according to the change of the load, and the energy saving space is relatively large.
These operating instructions can help the high and low temperature circulation box to be more energy efficient and use as much energy consumption as possible.
Related recommendations
-
Heat transfer oil secondary circulation system use instructions
2075The thermal oil secondary circulation system is equipped with various instruments and equipment for temperature control. When using it, you need to pay attention to its safety knowledge and safer operation. LNEYA heat transfer oil secondary circul...
View details -
LNEYA cooling and heating thermostat bath instructions
2621Circulating thermostatic water bath is water circulation and cooling function based on the increase in the water bath, can improve the precision of temperature control and temperature stability, can be widely used for drying, distillation, concent...
View details -
How to solve the fault of the ultra-low temperature refrigerator pressure controller?
2624If the industrial ultra-low temperature refrigerator encounters a controller-related failure during operation, if it is not resolved in time, the pressure controller may be unavailable. The pressure controller plays a very important role in the ul...
View details -
What are the influencing factors of the industrial refrigerator with minus 200 degrees?
2106In order to better use the industrial refrigerator with a temperature of minus 200 degrees, you need to understand some influencing factors and how to avoid it. The oil temperature will have an important effect on the viscosity of the industrial r...
View details
LNEYA Thermo Refrigeration Co.,Ltd












