High and low temperature circulation tank daily use instructions
During the operation of the high and low temperature circulation tank, some phenomena generated by the LNEYA protection device need to be observed. If some improper sounds and unexpected situations occur, we need to solve it in time.
The high and low temperature circulation tank is not connected to the power switch, forget to turn on the leakage circuit breaker, and turn the leakage circuit breaker to ON. There is no input from the power supply: the fuse is burnt. In order to ensure the safe and reliable operation of the refrigeration system and prolong the service life of the compressor, please pay attention to daily maintenance. Before starting the compressor, pay attention to whether the valve to be opened in the exhaust cut-off valve and its system is in the correct position, and check whether the power supply voltage and ambient temperature are within the specified range. During the operation of the compressor, the suction and exhaust pressure of the compressor should not exceed the range of use, and the operation sound of the compressor should be heard. Except that the intake valve and exhaust valve have clear pouring sound, other parts should not be knocked. When the sound is heard, it is found that the leak should be repaired in time. When the compressor is stopped for a long time, the refrigerant should be recycled to the reservoir and the exhaust shutoff valve should be closed.

The high and low temperature circulation tank adopts a fully closed pipeline design and adopts a high efficiency plate heat exchanger. It is applied to the temperature rise and temperature control of the glass reactor, metal reaction kettle and bioreactor, especially suitable for heat and release during the reaction process. Thermal process control. The high and low temperature circulation tank is applied to the temperature rise and temperature control of the glass reactor, the metal reaction kettle and the bioreactor, and is particularly suitable for controlling the heat demand and the heat release process during the reaction process.
Every accessory in the high and low temperature circulation tank is very important. Once the fault occurs, it needs to be solved in time. In the process of running, pay more attention to the maintenance in time to ensure the efficient operation of the accessories.
관련 권장 사항
-
유리 반응기에 대한 냉각 및 가열 시스템의 영향
1241유리 반응기는 부피가 작고 구조가 명확하며 유연한 방식으로 직렬 및 병렬로 편리하게 작동하여 다양한 공정 상황을 완벽하게 충족시킬 수 있으며 반응 경로에 금속 접촉이 없으며 인라인 ...
세부 정보 보기 -
고온 및 저온 장치 관련 기기 유지보수 지침
1157The liquid medium should be added before the high and low temperature circulation device is used. The liquid medium generally uses more than 95% alcohol, and the liquid medium cannot be lower than the working plate 20mm. The high and low temperatu...
세부 정보 보기 -
온라인 라이브 감사 활성화에 앞장선 LNEYA
1358Good products come from a strict manufacturing process. In March 2020, LNEYA took the lead in adopting the methods of cloud supervision and factory inspection, focusing on the display of LNEYA refrigeration heating temperature control device, TCU ...
세부 정보 보기 -
실험실 냉난방 서큘레이터 선택 가이드
1095실험실 냉각 및 가열 순환기 장비를 구매할 때 핵심은 생산 요구 사항을 충족하고 생산량을 가속화하는 것입니다. 따라서 장비 및 기술 솔루션의 특성을 이해해야합니다 ...
세부 정보 보기