High and low temperature circulation tank daily use instructions
During the operation of the high and low temperature circulation tank, some phenomena generated by the LNEYA protection device need to be observed. If some improper sounds and unexpected situations occur, we need to solve it in time.
The high and low temperature circulation tank is not connected to the power switch, forget to turn on the leakage circuit breaker, and turn the leakage circuit breaker to ON. There is no input from the power supply: the fuse is burnt. In order to ensure the safe and reliable operation of the refrigeration system and prolong the service life of the compressor, please pay attention to daily maintenance. Before starting the compressor, pay attention to whether the valve to be opened in the exhaust cut-off valve and its system is in the correct position, and check whether the power supply voltage and ambient temperature are within the specified range. During the operation of the compressor, the suction and exhaust pressure of the compressor should not exceed the range of use, and the operation sound of the compressor should be heard. Except that the intake valve and exhaust valve have clear pouring sound, other parts should not be knocked. When the sound is heard, it is found that the leak should be repaired in time. When the compressor is stopped for a long time, the refrigerant should be recycled to the reservoir and the exhaust shutoff valve should be closed.
The high and low temperature circulation tank adopts a fully closed pipeline design and adopts a high efficiency plate heat exchanger. It is applied to the temperature rise and temperature control of the glass reactor, metal reaction kettle and bioreactor, especially suitable for heat and release during the reaction process. Thermal process control. The high and low temperature circulation tank is applied to the temperature rise and temperature control of the glass reactor, the metal reaction kettle and the bioreactor, and is particularly suitable for controlling the heat demand and the heat release process during the reaction process.
Every accessory in the high and low temperature circulation tank is very important. Once the fault occurs, it needs to be solved in time. In the process of running, pay more attention to the maintenance in time to ensure the efficient operation of the accessories.
Related recommendations
-
Hot and cold dynamic constant temperature control equipment cryopump installation points
2291The performance of each component in the cold and heat source dynamic constant temperature control equipment is different. We must make full use of each accessory to make the equipment run better. The cryopump is one of the main accessories, and i...
View details -
Semiconductor refrigeration temperature control system accessories
2210In the evaporator, since the liquid evaporates in the evaporator of the semiconductor refrigeration temperature control system, the process from liquid to gas, due to the change of the load, some of the refrigerant may not be completely evaporated...
View details -
What are the conditions for the decarboxylation reaction? How to control the temperature of heating?
2567The decarboxylation of aromatic acids is easier than that of fatty acids. For example, benzoic acid can be decarboxylated by adding a little copper powder as a catalyst in quinoline solution and heating. When a strong electron-withdrawing group i...
View details -
High precision semiconductor incubator maintenance instructions
2521The high-precision semiconductor incubator is in the state of the evaporator as a gas refrigerant; after the adiabatic shrinkage of the shrinking machine, it becomes a high-temperature and high-pressure state, and the contracted gas refrigerant is...
View details
LNEYA Thermo Refrigeration Co.,Ltd