High and low temperature circulation tank daily use instructions
During the operation of the high and low temperature circulation tank, some phenomena generated by the LNEYA protection device need to be observed. If some improper sounds and unexpected situations occur, we need to solve it in time.
The high and low temperature circulation tank is not connected to the power switch, forget to turn on the leakage circuit breaker, and turn the leakage circuit breaker to ON. There is no input from the power supply: the fuse is burnt. In order to ensure the safe and reliable operation of the refrigeration system and prolong the service life of the compressor, please pay attention to daily maintenance. Before starting the compressor, pay attention to whether the valve to be opened in the exhaust cut-off valve and its system is in the correct position, and check whether the power supply voltage and ambient temperature are within the specified range. During the operation of the compressor, the suction and exhaust pressure of the compressor should not exceed the range of use, and the operation sound of the compressor should be heard. Except that the intake valve and exhaust valve have clear pouring sound, other parts should not be knocked. When the sound is heard, it is found that the leak should be repaired in time. When the compressor is stopped for a long time, the refrigerant should be recycled to the reservoir and the exhaust shutoff valve should be closed.
The high and low temperature circulation tank adopts a fully closed pipeline design and adopts a high efficiency plate heat exchanger. It is applied to the temperature rise and temperature control of the glass reactor, metal reaction kettle and bioreactor, especially suitable for heat and release during the reaction process. Thermal process control. The high and low temperature circulation tank is applied to the temperature rise and temperature control of the glass reactor, the metal reaction kettle and the bioreactor, and is particularly suitable for controlling the heat demand and the heat release process during the reaction process.
Every accessory in the high and low temperature circulation tank is very important. Once the fault occurs, it needs to be solved in time. In the process of running, pay more attention to the maintenance in time to ensure the efficient operation of the accessories.
Related recommendations
-
Influence of Freezing Oil on New Energy Vehicle Drive Motor Test System
2515The hazard of the refrigerating oil in the new energy vehicle drive motor test system increases the condensation temperature and the condensing pressure; the condenser heat transfer deteriorates. Because the oil film produced by the oil entering t...
View details -
How to deal with organic waste gas treatment refrigerant leakage?
2254In the process of organic waste gas treatment, if it is found that the refrigerant leaks, it is recommended to treat it in time. LNEYA organic waste gas treatment professional manufacturer then analyzes the knowledge of organic waste gas treatment...
View details -
New energy vehicle testing comprehensive test box filled with heat transfer oil
2491In order to ensure the correct operation of the machine, the new energy vehicle inspection integrated test box must ensure that no air bubbles remain in the system, ensure that the heat transfer medium outlet is connected to the lower interface of...
View details -
Core Maintenance Points of Ten High and Low Temperature Test Chamber Manufacturers
2076According to many years’ production experience of high and low temperature test chamber in Wuxi Guanya, it is found that many users are not very familiar with the maintenance of high and low temperature test chamber. As one of the top ten manufact...
View details
LNEYA Thermo Refrigeration Co.,Ltd