Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units
Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chillers and cool the compressor, we are the experts to develop water chiller refrigeration system 320/420 w / 430 w experts, so today LNEYA will recommend a few solutions for you:
Increase cooling water flow and heat ventilation of water tank and water tower:
Air-cooled water tank of industrial cold water machine and cooling water in industrial cooling towers are to cool the condenser and transfer heat which can take away the heat generated by the compressor work. If you can guarantee the cooling water flow rate and air cooling industry cold water machine water tanks, water chiller water tower cooling ventilation ability, you will keep cooling water temperature to within the limits defined, so as to maximize the cool the compressor.
Reduce the exhaust temperature of the refrigeration compressor directly:
You can start from decreasing compression ratio and the load of the compressor. Lower compression ratio will make compressor low efficient, but it can solve the problem of excess exhaust temperature of compressor.
Related recommendations
-
High and low temperature integrated machine equipment blockage instructions
2161If the high and low temperature integrated machine equipment is running for a long time, if it is not taken care of, it may cause the high and low temperature integrated machine equipment to be blocked. How to solve the equipment blockage? The fir...
View details -
Treatment of organic waste gas by condensation method
2427Condensation treatment of organic waste gas equipment should pay attention to its performance when selecting. It is very necessary to choose high-performance condensation method to treat organic waste gas. So what is the use of organic waste gas f...
View details -
What are the applications of Industrial temperature control machine chillers?
2520Industrial temperature control machine chillers are divided into oil-cooled and water-cooled according to the temperature and medium. The medium used is different for different temperatures, water can be selected for normal temperature, heat tra...
View details -
The main purpose of the ethylene glycol chiller for the heating and cooling unit of the reactor
2398The glycol chiller is suitable for high-purity metal, rare substance purification, laboratory environment simulation, magnetron sputtering, vacuum coating and other industries. Large cryogenic pump units can provide a cooling environment for labor...
View details
LNEYA Thermo Refrigeration Co.,Ltd