Selection and installation of the expansion valve for recirculating chillers
Regarding today’s topic, we have the
following analysis.
The selection of expansion valve plays an
important role in the performance of the recirculating chiller refrigeration
system. The correct choice of expansion valve will maximize the use of the evaporator
and make the evaporator always be matched to the heat load.
First, the selection of thermal
expansion valve.
In the recirculating chiller refrigeration
system, the selection and installation of the expansion valve is very
important. Only the correct selection and installation can ensure the normal
operation of the unit. Therefore, when selecting the expansion valve, we can
use the appropriate size of the thermal expansion valve according to the size
of the evaporator load and the evaporating temperature. The capacity of the
commonly used expansion valve is about 20% larger than the evaporator heat
load. For small chiller refrigeration systems, gas-filled thermal expansion
valves are generally used, and medium-sized recirculating chiller refrigeration
systems mostly use adsorption-filled or mixed-filled expansion valves.
Second, the expansion valve
installation.
1. The chiller expansion valve is installed
in front of the evaporator and is usually installed in a vertical position.
Considering the ease of installation and maintenance, the cooling loss is small
and should be as close as possible to the inlet of the evaporator.
2. The working
condition of the expansion valve for the recirculating chiller has a direct
relationship with the installation position of the temperature sensing package.
Because the expansion valve completely adjusts the opening size of the
expansion valve by the temperature change of the temperature sensing package.
The temperature sensor package is installed on the pipe at the outlet of the
chiller evaporator. As the evaporator outlet pipe grows, its superheat
gradually increases. Therefore, the position of the expansion valve temperature
sensing package is directly related to the amount of fluid supplied from the
expansion valve.
We, LNEYA, have been engaged in the
manufacturing and R&D of industrial refrigeration, heating and temperature
control equipment for 15 years and have experienced designers and equipment
maintenance personnel. The selection and installation of the expansion valve of
the recirculation chiller can be said to be very complete, which not only
reduces the failure rate of the equipment, but also allows users to avoid loss
of production capacity during use. If you have any questions or needs regarding
recirculation chillers, you can contact us at sales@lneya.com.
관련 권장 사항
-
혼합 탱크 냉각을 위한 냉각기는 어떻게 선택하나요?
1221혼합 탱크는 코팅, 의약품, 건축 자재, 화학 물질, 안료, 수지, 식품, 과학 연구 및 기타 산업에서 재료를 교반, 혼합, 혼합 및 균질화하는 데 사용됩니다. 혼합 탱크는 혼합 공정 중에 열을 발생시킵니다 ...
세부 정보 보기 -
올바른 냉온 서큘레이터를 선택하는 방법은 무엇인가요?
1098냉온 순환기는 제약 및 화학 산업에서 널리 사용되어 사용자에게 냉온 제어, 균일한 온도 및 일정한 온도를 제공합니다. 또한 원자로, 원자로 등을 직접 장착하여 ...
세부 정보 보기 -
Environmental description of large industrial freezer condenser
1156In industrial cold processing, large industrial freezers are one of the more used equipment. Among them, the condenser is one of the main components, and its performance is very important. Therefore, when choosing, everyone still needs to understa...
세부 정보 보기 -
How to improve the efficiency of water cooled chillers?
1242Water cooled chiller is a kind of mechanical equipment that uses water resources for refrigeration. In recent years, water-cooled chiller is more and more widely used at home and abroad, mainly because most modern industrial production needs to us...
세부 정보 보기