What Are The Characteristics Of Refrigeration Of Industrial Chillers?
If there is a high temperature difference between the inlet and outlet water, then a large external tank will be used to store cold water. In this case, the cooling water will not be directly from the cooler application. Deep into the outside of the tank is a “temperature buffer sort behavior”. Cold water tanks are much larger than internal ones. The cold water goes to the application of external fuel tank and come back as hot water. It can be traced back to external fuel tanks, not to industrial chillers.
산업용 냉각기 recycle is at constant temperature and pressure to increase stability and repeatability of water cooling equipment and instrument cleaners and conditions or clean water. Angle use and back of application of cooling of water flow.
An uncommon open-loop controlled industrial refrigerator is an open tank or oil pan at which the temperature of the liquid is continuously circulating. The liquid comes from the tank and goes back to the tank through the pump crew. It is an adjustable constant temperature sensory liquid temperature and circulation cooler to maintain constant temperature tank.
One of the new developments in industrial chillers is air cooling, not the use of cooling water. In this case, the condenser of industrial water chiller does not have cooling and hot air refrigerant, but uses cooling water. This development allows for more than 15% reduction in energy demand in coolers due to the small area of surface water. In addition, the noise level can be greatly reduced with the permission of the fans.
Most industrial chillers use cooling media for refrigeration, but some simple technologies that rely on air or water include cooling coil flow that regulates temperature. Water is a commonly used coolant in refrigeration process, although cooling mixtures (mainly with coolant additives to enhance cooling water) are often used.
관련 권장 사항
-
구체적인 작동 분석 산업용 냉동고 사용 시 제습 방법
1255산업용 냉동고를 사용하는 과정에서 냉동 시스템에 약간의 습기가있을 수 있습니다. 따라서 산업용 냉동고의 제습은 매우 중요하므로 제습하는 방법은 무엇입니까? 제습시 산업용을 구매하는 사용자는 ...
세부 정보 보기 -
Operation and Maintenance of Small Water Chiller Units
9722. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advanta...
세부 정보 보기 -
Take You To Know The Performance Of LNEYA Industrial Freezer Accessories
780Temperature Controller The temperature controller is used for control or protection of the unit. When the temperature reaches the set value, the switch automatically cuts off (or turns on) the circuit. In our products, temperature control is often...
세부 정보 보기 -
High precision semiconductor incubator maintenance instructions
1307The high-precision semiconductor incubator is in the state of the evaporator as a gas refrigerant; after the adiabatic shrinkage of the shrinking machine, it becomes a high-temperature and high-pressure state, and the contracted gas refrigerant is...
세부 정보 보기