Analysis of the causes of noise generated by the operation of low temperature chillers
Noise is common in the operation of industrial equipment. There are many reasons for noise, which may be caused by some environmental problems in the installation. When noise is generated, we must first confirm the cause and whether it is an internal component. The problem is raised because if a problem occurs and the replacement or repair is not stopped in time, the low temperature chiller will not work properly.
The environment and location of the device can cause noise problems, and if it is in a relatively small environment, the noise will be “amplified”. A smaller environment will make the normal operation sound louder and will sound out of normal operation. It is recommended that both air-cooled and water-cooled units be installed in a relatively open environment with no foreign objects around them. If the requirements are higher, the soundproof wall can be installed and ventilation and heat dissipation can be observed.
There is no flatness processing under the device position, which will result in displacement during normal operation, as well as vibration and shaking during normal operation. Under displacement conditions, the amplitude of the vibration will increase and a large amount of noise will be generated.
Due to the operational noise caused by the low temperature chiller itself, air coolers and water coolers are more prone to “noise” than the latter due to structural differences. It is well known that air-cooled chillers are cooled by a fan for the condenser, while the water cooler is cooled by a cold water tower system for the condenser. Compared to the noise of the cold water tower (usually placed at a high position, it is different from the position of the water cooler). The fan is noisy and integrated with the chiller main unit, so it is easier to feel the noise (can remove the blades or fill the bearings with smooth oil).
In addition, the compressor of a low temperature chiller is one of the sources of noise. The selected compressor can have low noise characteristics and the chiller noise must be low. Otherwise, the overall chiller will be noisy.
In addition to the noise figures of the chillers used in low-temperature chillers, whether it can be operated continuously for a long time, whether to add appropriate smooth oil, whether it can be regularly maintained, and whether the service life is too long is the key to balancing the noise elements of low-temperature chillers. Where. In addition, there are pumps for both air and water cooling. If the pump is running too loud, it may need to be cleaned.
Then, as an important part of the 저온 냉각기, in order to reduce losses and generate noise, we should always maintain to extend its service life and improve operational efficiency:
1. Check if the oil level of the fuselage and oiler is normal.
2. Check the movement flexibility of the oiler and the amount of oil injected
3. Check the oil leakage, water leakage and air leakage of the compactor and take corresponding measures to remove it.
4. Check that each valve is open.
5. Check that the vibration of the machine is normal. Otherwise, it is necessary to stop the inspection and scanning.
6. Check that the value of each meter is normal.
7. Check the smooth oil process (fine) filter and replace the fine filter according to the conditions. Stop cleaning the strainer.
If you have any knowledge of the use, maintenance, equipment prices, etc. of cryogenic chillers, please contact LNEYA and discuss: sales@lneya.com/LNEYA.COM.

관련 권장 사항
-
반도체 프로브 냉각 냉각기 시스템
1054반도체 테스트 냉각기 또는 반도체 테스트 냉각 시스템이라고도 하는 반도체 프로브 냉각기는 반도체 테스트 환경에 정밀한 온도 제어를 제공하도록 설계된 장치입니다. 중요한 역할을 하는 ...
세부 정보 보기 -
Small desktop sealed chiller troubleshooting solution
958Small desktop sealed chillers will have more or less failures after long-term use, so how can the compressor be solved if there are some faults? LNEYA specializes in the development and production of small desktop sealed chillers with a temperatur...
세부 정보 보기 -
Motor test bench environmental cabin option for new energy vehicles
978Passenger car motor and commercial vehicle motor test bench can complete the stall torque and locked rotor current test, temperature rise test, continuous electric working characteristic test, motor maximum speed test, motor over speed test and fe...
세부 정보 보기 -
Application of Chiller
1161With the rapid development of modern industrial technology, in order to improve production efficiency, improve product quality and reduce production costs, the requirement of temperature control in production process is becoming higher and higher....
세부 정보 보기