전체 방송국 검색

대형 물 냉각기

  • High Performance and Low Noise

These compressors not only perform excellently but also operate quietly. Even during long-term operation, they can run for over 100,000 hours without failure.

  • Intelligent Temperature Control

The unit features segmented or stepless energy regulation. It adjusts flexibly according to the thermal load requirements during production, ensuring optimal cooling efficiency.

  • Energy-Efficient Control

By using the outlet temperature of the refrigerant as a control point, the unit’s control center adjusts the compressor load by controlling the movement of the energy regulation valve, achieving actual energy savings.

실외 냉각기

난방 전력 3.5kW~15kW

온도 정확도 ±0.3℃

대형 냉각기

난방 전력 2.5kW~10kW

온도 정확도 ±0.3℃

스크류 워터 칠러

순환 펌프 최대 5m³/h~28m³/h 2bar

온도 정확도 ±0.5℃

스크류 냉각기 플랜트

순환 펌프 최대 2.4m³/h~12.1m³/h 2bar

온도 정확도 ±0.5℃

수냉식 스크류 냉각기

순환 펌프 최대 2.3m³/h~12m³/h 2bar

온도 정확도 ±0.5℃

산업용 워터 쿨러

순환 펌프 최대 2.3m³/h~12m³/h 2bar

온도 정확도 ±0.5℃

모델 LG2-75W LG2-100W LG2-140W LG2-180W LG2-230W LG2-280W
온도 범위  -25℃~5℃
냉각 용량
-20℃
kW 80 111 158 206 259 318
Kcal/hr*10³ 68.8  95.5  135.9  177.2  222.7  273.5 
전원 3N/400V/50HZ
(-20℃)에서 냉각 입력 전원 56 74  105  136  166  205
압축기 양식 반폐쇄형 더블 스크류 컴프레서
열 제어 범위 25%~100%
차가운 물 양식   판형, 건식, 오버플로 또는 낙하형 필름 열교환기
냉각수 용량T/H 24 32  46  59  75  92 
수압 강하 40~80
연결 크기 DN65 DN80 DN100 DN125
냉각수 양식 수평 관형 열교환기
냉각수 용량T/H 26 35 50 65 80 99
수압 강하 40~80
연결 크기 DN80 DN100 DN125 DN150

LARGE WATER CHILLER ‘S APPLICATIONS

일반적으로 생산 공정에서의 기계 냉각 및 스핀들 냉각, 제약 분야에서 다양한 약물 및 제조 공정의 온도 제어, 화학적 또는 실험실 결정화 및 합성과 같은 화학 반응의 온도 제어, 신에너지 자동차 테스트 및 반도체에 사용됩니다.

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

스크류 냉각기에 대한 세부 정보와 가격을 알아보려면 지금 바로 문의하세요.

온도 범위
Consider the production temperature requirements first. Different applications (such as air conditioning and low-temperature projects) have different temperature needs.
Cooling Capacity and Single Unit Cooling Capacity
The cooling capacity directly affects the energy efficiency and operating economy. When designing a chiller system, multiple units should be arranged to ensure production continues even if one unit is down.
Energy Consumption
Consider both electrical and steam consumption, especially for large systems. The goal is to maximize energy efficiency by considering the combined use of electricity, heat, and cooling.
Environmental Protection
Focus on the noise level and the impact of the refrigerants on the environment. Avoid using refrigerants that damage the ozone layer or are harmful to the environment, ensuring that the system meets environmental standards.
If you have any doubts about choosing the right chiller, feel free to contact us. Our 24/7 customer service team is available to provide professional consultation and offer custom-designed solutions.

The air cooled screw compressor chiller is mainly composed of the screw compressor, expansion valve, condenser, evaporator, and other components.
Below is the translation of the specific parts and their functions:
스크류 컴프레서  
It is the power source of the air-cooled screw chiller system. Its main function is to extract the vapor from the evaporator in a timely manner, maintain low temperature and low pressure, and increase the pressure and temperature of the refrigerant vapor through compression, creating conditions for the heat transfer of the refrigerant vapor to the external environment.
콘덴서  
The air-cooled screw chiller uses a finned condenser. The condenser is a heat exchange device that works by transferring the heat of the high-temperature, high-pressure vapor discharged from the compressor to the surrounding cooling medium.
확장 밸브  
Since the high-pressure, normal-temperature refrigerant liquid cannot be directly sent into the low-temperature, low-pressure evaporator, it needs to be depressurized and its temperature reduced. Therefore, the expansion valve is used to obtain low-temperature, low-pressure refrigerant, which is then sent to the evaporator to absorb heat and vaporize.
 증발기  
Similar to the condenser, the evaporator is also a heat exchange device. It evaporates the low-temperature, low-pressure refrigerant liquid into vapor, absorbs heat from the cooled medium, reduces the temperature of the cooled medium, and provides low-temperature chilled water to achieve cooling. The evaporator, like the condenser, must have a sufficiently large area to work effectively.

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!

아래 QR 코드를 통해 계정 관리자를 추가하세요