전체 방송국 검색

실외 냉각기

  • Strong Environmental Adaptability
    Even in harsh environments, outdoor chillers can maintain fast operation and help maximize profits over the long term.
    Larger Applicable Space
    Outdoor chillers can operate efficiently even without abundant water resources, offering high cost-performance.
    Lower Failure Rate
    With a simple structure, the likelihood of malfunction is minimal, reducing future maintenance costs.
    Excellent Performance
    Outdoor chillers offer high stability, ensuring high operational efficiency while achieving rapid cooling in a short time and providing excellent cooling effects.

Boasting over 80 technical patents and industry-leading cascade refrigeration technology, as well as rapid temperature rise and fall technology, our chillers are the ideal choice for a variety of applications.

모델 LG1-75W LG1-100W LG1-140W LG1-180W LG1-230W LG1-280W
온도 범위 5℃~30℃
냉각 용량
7℃
kW 236 328 468 608 762 936
Kcal/hr*10³ 202.9  282.1  402.5  522.9  655.3  805.0 
전원 3N/400V/50HZ
(7℃)에서 냉각 입력 전원 64 84  120  155  191  236
압축기 양식 반폐쇄형 더블 스크류 컴프레서
열 제어 범위 25%~100%
차가운 물 양식 판형, 건식, 오버플로 또는 낙하형 필름 열교환기
냉각수 용량T/H 40  56  80  104  131  160 
수압 강하 40~80
연결 크기 DN80 DN100 DN125 DN150
냉각수 양식 수평 관형 열교환기
냉각수 용량T/H 51  71  101  131  163  201 
수압 강하 40~80
연결 크기 DN80 DN100 DN150 DN200

실외 냉각기

난방 전력 3.5kW~15kW

온도 정확도 ±0.3℃

대형 냉각기

난방 전력 2.5kW~10kW

온도 정확도 ±0.3℃

스크류 워터 칠러

순환 펌프 최대 5m³/h~28m³/h 2bar

온도 정확도 ±0.5℃

스크류 냉각기 플랜트

순환 펌프 최대 2.4m³/h~12.1m³/h 2bar

온도 정확도 ±0.5℃

수냉식 스크류 냉각기

순환 펌프 최대 2.3m³/h~12m³/h 2bar

온도 정확도 ±0.5℃

산업용 워터 쿨러

순환 펌프 최대 2.3m³/h~12m³/h 2bar

온도 정확도 ±0.5℃

OUTDOOR CHILLER’S APPLICATIONS

일반적으로 생산 공정에서의 기계 냉각 및 스핀들 냉각, 제약 분야에서 다양한 약물 및 제조 공정의 온도 제어, 화학적 또는 실험실 결정화 및 합성과 같은 화학 반응의 온도 제어, 신에너지 자동차 테스트 및 반도체에 사용됩니다.

글로벌 서비스

30,000명 이상의 고객에게 서비스를 제공했습니다.
20개국 이상에 수출되었습니다.

인증 특허

CE 인증, SGS 인증, ISO 인증을 획득했습니다.

판매 후 서비스

포괄적인 기술 교육을 제공합니다.
연중무휴 솔루션으로.

전문 팀

2010년에 설립되어 15년의 업계 경력을 보유하고 있습니다.
20%의 직원이 기술자입니다.

품질 관리

육안 검사.
성능 테스트.
전기 안전 테스트.

Outdoor Water-Cooled Chiller
Outdoor Water-cooled Chillers play a role in the evaporation process. The water and gas produced by the system are sent to the evaporator, where they collect the unwanted heat. The heat is then returned to the evaporator, where the collected thermal energy is stored. Afterward, the refrigerant absorbs this heat and converts it into condensation water. In other words, the condenser sends all the collected heat to the cooling tower, and the hot air is released through the cooling coils, dissipating the heat into the atmosphere Outdoor Air-Cooled Chiller
Air-cooled chillers transfer heat to the air. These units use aluminum fins to guide the airflow from the outdoor chiller fan and copper tubes to guide the refrigerant. The system circulates external air through the condenser coils, mechanically dissipating heat directly into the atmosphere..

LNEYA Commitment:
From the date of acceptance, we offer a one-year free warranty. During the warranty period, all repair and spare parts costs will be covered by us. However, if the damage to the Outdoor Chiller is caused by human factors, the cost of spare parts will be charged at cost price.
After the warranty period, we provide lifetime maintenance services, with charges based on the actual repair costs.

*
*
제출하기....
성공적으로 제출되었습니다!
제출에 실패했습니다! 나중에 다시 시도하십시오.
이메일 오류!
전화 오류!

아래 QR 코드를 통해 계정 관리자를 추가하세요