Is the choice of a centrifugal pump or a volumetric pump in a pharmaceutical laboratory?
Performance:
In order to be able to select the type of pump that is suitable in the pharmaceutical laboratory, it is necessary to have a deep understanding of its performance and understand the difference in its specific working principle. To this end, we must understand that the centrifugal pump is dependent on the pressure (or The variable flow phenomenon of the indenter, while the positive displacement pump has a more or less constant flow phenomenon independent of the pressure.
Viscosity:
The centrifugal pump and the positive displacement pump are also different in viscosity, and the flow rate drops when the viscosity rises, and the positive displacement pump actually causes an increase in the flow rate. This is because the higher viscosity liquid fills the voids in the volumetric pump, resulting in higher volumetric efficiency.
Efficiency:
In pharmaceutical laboratories, it is necessary to consider the effect of pressure on the equipment. After all, different pumps have different characteristics. Different efficiencies will increase the pressure of the pump. For volumetric pumps, as the pressure increases, Efficiency will actually increase, and centrifugal pumps have a better efficiency point. On both sides of this point, the overall pump efficiency will drop significantly.
Entrance conditions:
The pharmaceutical laboratory has different conditions for the inlets of these two types of pumps. The centrifugal pump needs to reserve a certain amount of liquid in the pump to form a pressure difference. The liquid-free dry pump cannot be started by itself, due to the volume. The pump agitates the liquid by the expansion and contraction of the liquid volume, and the negative pressure is formed at the inlet, so the volumetric pump can initiate the perfusion. In some cases, this is the decision whether to choose the volumetric pump or the centrifugal pump. Elements.
The selection of different pumps in the pharmaceutical laboratory is to be selected according to their own needs. It takes a lot of time to get the right choice to get a higher benefit.
Related recommendations
-
What are the effects of power failure on liquid nitrogen cryogenic cold box?
1871Different industries have different temperature requirements for cryogenic cryostats. Of course, there are many types of cryogenic cryostats. The refrigeration methods used in different industries are different. LNEYA uses compressor refrigeration...
View details -
Basic structure manual of industrial chiller
2416Industrial chillers are composed of compressors, condensers, evaporators, expansion valves and other accessories. 1. Compressor: In the industrial chiller system, the compressor is the power to ensure refrigeration. The compressor is used to incre...
View details -
Semiconductor Test Temperature Cycle Chiller Development
2290The semiconductor chip IC industry is currently a relatively new industry in China. As the requirements of the chip industry become higher and higher, the test difficulty is also constantly strengthened. To this end, LNEYA introduced the semicondu...
View details -
Low temperature chilled lubricant selection considerations
2510When you use a cryogenic chilled, you definitely want to know about all aspects of the cryocooler. But one of the things that needs everyone's attention is that the type of lubricant for the chilled is chosen because there are many influencing fac...
View details
LNEYA Thermo Refrigeration Co.,Ltd