Is the choice of a centrifugal pump or a volumetric pump in a pharmaceutical laboratory?
Performance:
In order to be able to select the type of pump that is suitable in the pharmaceutical laboratory, it is necessary to have a deep understanding of its performance and understand the difference in its specific working principle. To this end, we must understand that the centrifugal pump is dependent on the pressure (or The variable flow phenomenon of the indenter, while the positive displacement pump has a more or less constant flow phenomenon independent of the pressure.
Viscosity:
The centrifugal pump and the positive displacement pump are also different in viscosity, and the flow rate drops when the viscosity rises, and the positive displacement pump actually causes an increase in the flow rate. This is because the higher viscosity liquid fills the voids in the volumetric pump, resulting in higher volumetric efficiency.
Efficiency:
In pharmaceutical laboratories, it is necessary to consider the effect of pressure on the equipment. After all, different pumps have different characteristics. Different efficiencies will increase the pressure of the pump. For volumetric pumps, as the pressure increases, Efficiency will actually increase, and centrifugal pumps have a better efficiency point. On both sides of this point, the overall pump efficiency will drop significantly.
Entrance conditions:
The pharmaceutical laboratory has different conditions for the inlets of these two types of pumps. The centrifugal pump needs to reserve a certain amount of liquid in the pump to form a pressure difference. The liquid-free dry pump cannot be started by itself, due to the volume. The pump agitates the liquid by the expansion and contraction of the liquid volume, and the negative pressure is formed at the inlet, so the volumetric pump can initiate the perfusion. In some cases, this is the decision whether to choose the volumetric pump or the centrifugal pump. Elements.
The selection of different pumps in the pharmaceutical laboratory is to be selected according to their own needs. It takes a lot of time to get the right choice to get a higher benefit.
Related recommendations
-
How does the ultra-low temperature test chamber control static electricity?
2750In order to control the static quality of the ultra-low temperature test chamber, the ultra-low temperature test chamber needs to control the static electricity better. How does the LNEYA ultra-low temperature test chamber control the static elect...
View details -
10hp freezer pipe cleaning instructions
2050The 10hp freezer is an industrial cold processing equipment from LNEYA. In the process of cooling using a chiller, if the pipeline is not cleaned properly, the refrigerator will be used, so the pipeline cleaning needs to be in place. Remove the he...
View details -
Lneya Semiconductor Refrigeration Heating Circulation Wind System Test Description
2371There are many test items in the refrigeration and heating circulating air system for semiconductors. So, how much do users know about the out-of-channel testing of the semiconductor refrigeration and heating circulating air system? The out-of-cha...
View details -
Closed cycle heating system temperature deviation description
2071If the temperature deviation occurs in the closed cycle heating system during use, it is necessary to check to see if there is any problem in each link, and solve the problem in time. In the steady state, the closed loop heating system displays th...
View details
LNEYA Thermo Refrigeration Co.,Ltd