The importance of chiller compressors
In the operation of the precision chiller, the compressor is a more important part. If we want to understand the chiller, we have to understand the compressor.
Most precision chiller compressors have a thermal switch inside. The function of this switch is to disconnect the power supply line to the motor of the compressor when the temperature of the compressor exceeds the set value, and it can be turned on until the compressor cools down. The compressor just works. This is the compressor’s built-in protection, the reasons for this and the solution.
The refrigeration system of the precision chiller is short of refrigerant. When the refrigerant is insufficient, the refrigerant returning to the compressor will be overheated, causing the compressor as a whole to heat up, causing the thermal switch to act, resulting in thermal protection of the compressor. Solution: Make up the refrigerant, and the return pipe of the compressor should be cool when it is turned on.
If the condensing pressure of the precision chiller compressor is too high, the cooling water or the high ambient temperature will make the compressor discharge pressure too high, resulting in an excessively high discharge temperature, thus causing the compressor to overheat. Solution: Clean the condenser, or increase the cooling water flow pressure.
The selection is wrong, the selection is small. When the compressor is too small, there will be a small horse-drawn cart, the chiller will never reach the set temperature, and the compressor will continue to work until the compressor is thermally protected. Solution: To re-select a new chiller, there must be an amplification factor to ensure that the chiller can reach the set temperature and stop.
The motor of the compressor of the precision chiller is faulty, and the insulation of the enameled wire is poor, which will cause the compressor current to be too large, and it will also be thermally protected. Solution: Contact the manufacturer to repair the compressor or replace the compressor.
If the compressor of the precision chiller fails, please ask a professional to handle it according to the specific fault treatment, and do not repair it without permission.
Related recommendations
-
Selection method of 0℃~5℃ freezing liquid for industrial ultra-low temperature chiller
1981As the requirements for process production become higher and higher, industrial ultra-low temperature chillers are required to provide cryogenic liquid below 5 degrees or even more than minus 100 degrees in some chemical process synthesis, reactor...
View details -
The Analysis Of Ultra Low Freezer’S Price
2310What are the characteristics and functions of ultra low freezer: 1. Ultra low freezer can prevent the precision of machine equipment from being influenced by the change of oil temperature in the process of operation. 2. Ultra low freezer can preve...
View details -
Control method for semiconductor test chiller to meet temperature requirements
2260The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to make chemical reactions proceed stably; the electronic...
View details -
ISG/TM Motor Test Cooling System High Voltage Failure and Treatment Measures
2718The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
View details
LNEYA Thermo Refrigeration Co.,Ltd