How to install -60°C cryogenic chiller manufacturers equipment
-60℃ cryogenic chiller
manufacturers are used in the refrigeration and chemical industry, so what
issues should be paid attention to during installation? LNEYA professional
manufacturers tell you that you should install according to the instruction
manual.
For the -60℃cryogenic chiller
compressor (unit) that has been tested at the factory and is protected by
rust-proof seals and has good pre-installation protection measures, it can be
directly installed, the protection measures are invalid, or the compressor (unit)
has obvious defects. Check it and install it after confirming that it meets the
factory manufacturer’s factory standards.
-60℃ cryogenic chiller
compressor (unit) should check the position of the foundation and anchor bolt
holes before it is in place, it should meet the requirements of the design
documents; it should be installed in the foundation and bracket according to
the connection method required by the design and equipment technical documents.
Welding shall not be used on hangers and on the design and equipment technical
documentation. The installation should meet the requirements of the equipment
technical documents. When leveling is required, the horn should be used. The
installation should keep the body stable and should not exceed the inclination
angle of the technical documentation of the equipment. Do not invert.
-60℃ cryogenic chiller
compressor (unit) manufacturer to ensure that the compressor does not corrode
after leaving the factory and before use, no impurities, more inert gas for sealing
treatment, so as long as the seal is intact, no obvious defects can be directly
installation. For small, lightweight-50-degree cryogenic unit compressors
(units), manual handling can be carried out during the installation process.
Due to exceeding the limit angle or inversion, internal
irreparable damage may occur, so standard handling is required. Refrigeration
auxiliary equipment such as intercooler, gas-liquid separator, oil separator,
liquid receiver, low-pressure circulating reservoir, oil collector, chiller,
condenser, etc. in the refrigeration system shall be installed in accordance
with current standards.
-60℃ cryogenic chiller
manufacturers Wuxi Guanya (LNEYA) will be arranged at the factory, the
corresponding instructions to follow the equipment, the user can install
according to the instructions.
Related recommendations
-
Battery test cooling device Chiller common configuration instructions
2444Under normal use, the battery test cooling device Chiller needs to be discovered in time when any part of the abnormality occurs. This requires a clear understanding of the basic configuration of the battery test cooling device Chiller. The batter...
View details -
What are the temperature control performance of laboratory recirculating chillers
2174The laboratory recirculating chiller is atypical cooling circulator with heating function to ensure the repeatability oflaboratory results. There are water-cooled or air-cooled refrigerators, whichcan be placed in a laboratory fume hood or set ...
View details -
Pharmaceutical chemical industry application – Heating Reactor Temperature Control
2183The pharmaceutical chemical industry involves many chemical reactions. The traditional heating reactor temperature control work efficiency is relatively low, the production cost is relatively high, and the device is relatively cumbersome. To this ...
View details -
Laboratory crystallization water chiller
1851Laboratory crystallization water chiller is a device specially used in laboratory environment to control the temperature conditions during crystallization. This equipment is mainly used in the research and development process of chemistr...
View details
LNEYA Thermo Refrigeration Co.,Ltd