The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chillers, cryogenic screw chillers, central air-conditioning units, chillers, water-cooled chillers and air-cooled chillers. Its operation situation will determine the practical refrigeration ability and control accuracy of the low temperature chiller system. However, most chillers use electronic expansion valves or thermal expansion valves as a saving arrangement of system. Controlling the superheat of the compressor inlet is most primary. However, due to the positioning in this planning, the electronic expansion valve can not fully exert the control efficacy of system accuracy. During the operation of low temperature chiller system, control can complete the optimal output control of system cooling capacity, but as is always the case, it can’t be completely exerted to output control system cooling capacity when the temperature is close to the equipment policy. the accuracy of the system can’t be ensured. Although the precision has been improved when using the method of PID control, as a whole, there is still a lot of room for improvement.
Equipment and Planning of Electronic Expansion Valve
In the low temperature chiller system, the electronic expansion valve is generally used as a general saving arrangement to control the superheat of compressor. It is usually equipped between the evaporator inlet and the condenser outlet. According to the superheat of compressor inlet, the size of the adjustable opening is analyzed and judged in real time, and the optimal control of superheat is completed to reach the optimal output of system cooling capacity. However, when the control needs to be accurate , due to the constraints of superheat, the best ability of refrigeration output control is often not brought into play, and the system temperature control accuracy is poor.
Related recommendations
-
Low temperature heating control chip and other detection methods
2240With the research and development of chip technology, chip detection technology is also maturing. LNEYA's low-temperature heating control chip technology is applied in chip detection. In addition to this type of detection technology, there are oth...
View details -
Configuration form of circulating heating unit for laboratory
2016The standard model of the circulating heating unit for LNEYA laboratory is: SUNDI, the temperature range is from room temperature to minus 120 degrees Celsius, and the capacity can be divided into 5L, 10L, 20L, 30L, 40L, 50L, 80L, 100L, larger cap...
View details -
Small coup to deal with ice blockage of high and low temperature liquid circulating chillers
1712In the operation of high and low temperature liquid circulating chillers, ice blockage is a relatively common fault. Based on the experience of relevant manufacturers, we have specially compiled relevant tips for dealing with ice jams. In the pip...
View details -
Application of Microchannel Reactor Temperature Control System in the Laboratory
1869Application of Microchannel Reactor Temperature Control System
View details
LNEYA Thermo Refrigeration Co.,Ltd