The Use of Electronic Expansion Valve in Low Temperature Chiller Systems
In the low temperature chiller system, the electronic expansion valve plays a key role in controlling the operating power of the system in cooperation with compressors, condensers, evaporators, water-cooled screw chillers, air-cooled screw chillers, cryogenic screw chillers, central air-conditioning units, chillers, water-cooled chillers and air-cooled chillers. Its operation situation will determine the practical refrigeration ability and control accuracy of the low temperature chiller system. However, most chillers use electronic expansion valves or thermal expansion valves as a saving arrangement of system. Controlling the superheat of the compressor inlet is most primary. However, due to the positioning in this planning, the electronic expansion valve can not fully exert the control efficacy of system accuracy. During the operation of low temperature 냉각기 시스템, control can complete the optimal output control of system cooling capacity, but as is always the case, it can’t be completely exerted to output control system cooling capacity when the temperature is close to the equipment policy. the accuracy of the system can’t be ensured. Although the precision has been improved when using the method of PID control, as a whole, there is still a lot of room for improvement.
Equipment and Planning of Electronic Expansion Valve
In the low temperature chiller system, the electronic expansion valve is generally used as a general saving arrangement to control the superheat of compressor. It is usually equipped between the evaporator inlet and the condenser outlet. According to the superheat of compressor inlet, the size of the adjustable opening is analyzed and judged in real time, and the optimal control of superheat is completed to reach the optimal output of system cooling capacity. However, when the control needs to be accurate , due to the constraints of superheat, the best ability of refrigeration output control is often not brought into play, and the system temperature control accuracy is poor.
관련 권장 사항
-
Heat transfer oil cleaning instructions in the heat transfer oil secondary circulation system
1132The heat transfer oil secondary circulation system uses the heat transfer oil as the medium to carry out the refrigeration and heating temperature control. Then, when the user cleans the heat transfer oil in the heat transfer oil secondary circula...
세부 정보 보기 -
Description of high and low temperature circulation tank refrigeration process
1416In the process of using high and low temperature circulating tanks, there may be some minor problems due to improper use, and there may be problems in the refrigeration process of Wuxi Guanya high and low temperature circulating tanks, and then we...
세부 정보 보기 -
100p Freezer Instructions of LNEYA
1244When the user buys and uses 100 freezers, LNEYA will have relevant instructions for use and will be sent to the user along with the device. So, what should I pay attention to when using the 100p freezer? When receiving the equipment, the user shou...
세부 정보 보기 -
공냉식 냉각기의 주요 적용 분야
963국내외 산업용 냉각기 시장에서 가장 일반적인 산업용 냉각기 장비는 크게 두 가지 유형으로 나눌 수 있으며, 한 유형은 산업용 공냉식 냉각기, 다른 유형은 산업용 물 공동 냉각기입니다 ...
세부 정보 보기