The reason for the high pressure alarm of the TCU integrated temperature control unit
When the TCU integrated temperature control unit is used, it needs to be used according to the instructions in detail. Once problems are encountered, they need to be dealt with in time. Generally speaking, if we encounter a high pressure alarm from the compressor, then we need to carefully analyze various reasons. The reasons include more refrigerant filling, poor condensation effect, electrical failure and many other reasons. So, how should it be handled?
1. There is a lot of refrigerant filling: the main manifestation is that the pressure of suction and exhaust and balancing is too high, and the pressure of the compressor operating current is too large. When in use, it is necessary to ensure its exhaust and balanced pressure according to the rated working conditions, and to ensure that the operating current discharges the refrigerant until the performance is normal.
2. The pipeline filter is blocked or too thin, and the water passing capacity is limited. A suitable filter should be selected and the filter screen should be cleaned regularly; or the pump should be small and not matched with the system.
4. False alarms caused by electrical faults, due to damp, poor contact or damage to the high-voltage protection relay, damp or damaged unit electronic boards, and false alarms caused by communication failures. For this kind of false fault, the fault indicator on the electronic board is often not bright or slightly bright, the manual reset of the high-voltage protection relay is invalid, the running current of the compressor is normal, and the suction and exhaust pressure is also normal.
5. At this time, the expansion valve should be gradually opened, and the opening process should not be too fast to prevent the copper tube in the evaporator from being damaged by too much liquid supply. Wait for a few minutes until the high and low pressure of the unit are balanced. At this time, a lot of white foam can be seen from the sight glass of the evaporator, which means that the oil has entered the evaporator from the condenser.
If the process temperature control unit you are using is the ZLF or SR series of our TCU, you can contact us if you have any questions.
Related recommendations
-
How to choose the price of semiconductor constant temperature system?
2184Now, it can be said that most of the industrial productions require semiconductor constant temperature systems to provide professional refrigeration. An efficient semiconductor constant temperature system can provide great help for various industr...
View details -
Small high and low temperature impact test chamber volume selection instructions
2476When the test product (components, components, components or complete machine) is placed in a small high and low temperature impact test chamber for testing, in order to ensure that the atmosphere around the test product can meet the environmental...
View details -
RF chip high and low temperature automatic test machine control system description
2551Based on the continuous development of the semiconductor chip industry, LNEYA RF chip high and low temperature automatic test machine is also promoted to consumers. So, what do you know about the RF chip high and low temperature automatic tester s...
View details -
After Adding A Backwater to the Heater, Hot Water Will Come Out Anytime and Anywhere in Winter
1794The principle is also simple. A water pipe is added at the outlet of the hot water pipe to form a closed circuit. The recirculation pump is connected to the water heater. When the tap is turned on, the circulating pump automatically pumps the cold...
View details
LNEYA Thermo Refrigeration Co.,Ltd