How to solve the phenomenon of ultra-low temperature freezer card cylinder?
If the ultra-low temperature freezer room fails during operation, it needs to be solved in time. If it is similar to the related phenomenon, it may be that the frozen oil does not come up, and the operator needs to solve it in time.
Ultra-low temperature freezer compressor compressor card cylinder processing method is more, increasing the capacitance is one of the common methods, simply speaking, the original capacitor and a capacitor or a large point of capacitance to increase the starting torque to make the compressor easier Run it up, pay attention: the compressor will shut down immediately after two or three seconds.
Ultra-low temperature freezer compressor card cylinder tapping method, generally choose wooden hammer or select available objects in place. The hammer hits the three solder joints on the body when the press is started. But pay attention, you can’t knock deformation. Gently tap the compressor casing to slightly loosen the stuck part, sometimes start the operation or increase the power supply voltage by 10%, and start the impact multiple times. This method can solve the problem of insufficient lubrication of the card cylinder. The compressor of the chiller is particularly effective. The ultra-low temperature freezer compressor card cylinder can also adopt the strong lifting method, connect a plug, L is directly connected to the C terminal, N is connected to the M terminal, and the other is connected to the branch line N1. The power is turned on to let the N1 touch the starting end of the compressor. .
The pneumatic shock method can be used to separate the compressor separately, and the compressor is supplied with a reaction force of 0.1 MPA from the high pressure pipe. The loose shaft mechanism is loosened. Rinse for 5 minutes. Then use the above method. Usually, there is a scale inside the compressor, or a card cylinder caused by dirty things. The above does not work. The compressor is removed and the oil is poured out. Add kerosene, then pour it out, once in a row, the purpose is to clean the dirty things inside. After washing, put the compressor upside down for 12 hours, pour the kerosene and volatilize it. Then add the frozen oil, pick up the compressor and then a few times on the ground to loosen the parts. Then use the above method to start.
Regardless of the failure of the ultra-low temperature freezer, the user needs to solve the problem in a timely and effective manner. If another unknown fault occurs, contact the manufacturer’s technical personnel for resolution.
Related recommendations
-
-
LNEYA star refrigeration heating system SUNDI-320/420W/430W
2267Today, I will introduce the model of LNEYA's refrigeration heating system: SUNDI-320/420W/430W. It has three kinds of medium temperature range: -30°C~180°C; -40°C~180°C; -40°C~200°C. The control system is programmed to program up to 10 programs...
View details -
[Invited to visit] CPHI CHINA 2019, Wuxi Guanya W5P22 booth is looking forward to your arrival!
2347On June 18-20, 2019, the 19th World Pharmaceutical Raw Materials China Exhibition - CPhI China 2019 will re-enter Shanghai New International Expo Center. CPhI China World Pharmaceutical Raw Materials China Exhibition is an international, high-qual...
View details -
The difference between a large refrigeration and heating circulator and a test chamber
20011. For the high temperature test under special circumstances, the high and low temperature test chamber may not meet the requirements. Generally speaking, the high temperature upper limit of the high and low temperature test box is 200 ℃, and its ...
View details
LNEYA Thermo Refrigeration Co.,Ltd