TCU temperature control model selection and technical parameter description
TCU temperature control is also a two-cycle unit single-fluid temperature control system. When selecting the model, it is very important for the whole temperature control reaction. Only the appropriate reaction system is used to exotherm and absorb the whole reaction process. The heat responds to the entire control, so the choice of model is very important.
TCU temperature control model: SR-10
Model SR-10 with operating temperature range of -120~200°C, suitable reaction vessel is 50L-250L, circulating pump flow pressure is controlled at 3m3/h1.5bar, circulating pump can not be adjusted, auxiliary heating power is 10KW, pre- The interface of the heat exchange module is DN25, and electric power, steam, hot oil, hot water, cooling water, chilled water and ultra-low temperature medium can be used as primary energy.
TCU temperature control model: SR-20
Model SR-20 with operating temperature range of -120~200°C, suitable reaction vessel is 100L-500L, circulating pump flow pressure is controlled at 2.4~6.6m3/h1.5bar, circulating pump control can be adjusted by frequency or fixed speed. The auxiliary heating power is 20KW, and the interface of the preheating heat exchange module is DN32.
TCU temperature control model: SR-38
Model SR-38 with operating temperature range of -120~200°C, suitable reaction vessel is 300L-1000L, circulating pump flow pressure is controlled at 5~12m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 38KW, and the interface of the preheating heat exchange module is DN40.
TCU temperature control model: SR-60
Model SR-60 with operating temperature range of -120~200°C, suitable reaction vessel is 500L-2000L, circulating pump flow pressure is controlled at 11~25m3/h2.5bar, circulating pump control can be adjusted by frequency or constant speed, auxiliary The heating power is 60KW, and the interface of the preheating heat exchange module is DN65.
TCU temperature control model: SR-95
Model SR-95 with operating temperature range of -120~200°C, suitable reaction vessel is 1000L-5000L, circulating pump flow pressure is controlled at 20~50m3/h2.5bar, circulating pump control can be adjusted by frequency or fixed speed, auxiliary The heating power is 95KW, and the interface of the preheating heat exchange module is DN80.
In addition, the energy conversion of TCU temperature control is carried out by heat exchanger and electric heating. In the temperature control mode selection, the material temperature control and jacket temperature control can be freely selected, and the material temperature control accuracy is ±1 °C. Inch / inch color touch screen. The temperature control of the whole TCU is a fully enclosed system. There is no oil mist at high temperature and no moisture in the air at low temperature. The TCU temperature control system does not increase the fluid pressure due to high temperature during operation, and automatically supplements the heat transfer medium at low temperature.
Related recommendations
-
Performance Test of Household Refrigerator Designed by Environmental Chamber Sales
2482Many performance items of household refrigerators are tested under a specific environmental condition. The thermal condition of the air distribution in the environmental chamber is more severe than that in the general artificial constant temperatu...
View details -
New energy vehicle testing comprehensive test box filled with heat transfer oil
2466In order to ensure the correct operation of the machine, the new energy vehicle inspection integrated test box must ensure that no air bubbles remain in the system, ensure that the heat transfer medium outlet is connected to the lower interface of...
View details -
Air-cooled and water-cooled methods of cooling and heating circulators
2316The cooling heating circulator is controlled by high and low temperature during operation. After the user runs at high temperature and low temperature, it can be heated with heat transfer oil, which is water-cooled and air-cooled. 1. It belongs ...
View details -
Semiconductor refrigeration heating cycle air system test description
2046There are many test items in the refrigeration and heating circulating air system for semiconductors. So, how much do users know about out-of-channel testing? The out-of-channel test of the cooling and heating circulating air system for semiconduc...
View details
LNEYA Thermo Refrigeration Co.,Ltd