Cascade cryogenic refrigeration system is a low-temperature refrigeration system which uses more than two refrigerants and combines them with heat exchangers (condenser evaporators) in more than two systems. For binary cascade refrigeration system chiller, it consists of two separate refrigeration systems. One is the high temperature system, the other is the low temperature system. The cryogenic system is used to cool the environmental laboratory, while the high-temperature system is used to cool the exhaust gas of the cryogenic system and condensate it at a lower temperature. This also achieves the purpose of reducing compression ratio and improving gas transmission coefficient.
The advantages of the industrial chiller for cascade cryogenic refrigeration system are the use of medium-pressure refrigerants suitable for high-temperature systems and high-pressure refrigerants suitable for low-temperature systems. The specific capacity of high pressure refrigerant gas at low temperature is much smaller than that of medium pressure refrigerant. Therefore, the refrigeration capacity of the same type of compressor for cascade refrigeration is several times larger than that of two-stage compression refrigeration at low temperature. The use of cascade refrigeration system water cooler can save a lot of investment and building area. Moreover, the high-pressure refrigerant operates at a low temperature with an inhalation pressure greater than or close to one atmosphere, and it does not often infiltrate into the system like a two-stage cryogenic system.
The cascade refrigeration system can be used for industrial water chillers, except that the user’s requirement varies greatly and the ambient temperature is above – 55 C. At present, there are more and more cold sources using cascade refrigeration system as cryogenic experimental equipment.
관련 권장 사항
-
How to Solve the Problem of Compressor Noise in Industrial Low Temperature Chiller?
1210In industrial low temperature chiller, compressor operation will produce noise, but only thedifference of sound size. Generally speaking, there will be some problems if the noise is too large. So, how to solve the problem of compressor noise?Gener...
세부 정보 보기 -
Vocs condensing separation equipment expansion valve maintenance instructions
959Once the expansion valve of the vocs condensing and separating device fails, if the solution is not solved in time, the entire vocs condensing and separating device may be unavailable. Therefore, the failure of the expansion valve of the vocs cond...
세부 정보 보기 -
The role of the chemical and pharmaceutical reactor chiller
1308의약품 합성 및 정밀 화학 작업 과정에서 우리는 종종 산화 반응 및 산-염기 중화와 같은 강력한 발열 반응에 직면합니다. 이러한 강한 발열 반응의 경우 제어가 부적절하거나 제어가 부적절하면 ...
세부 정보 보기 -
온도 충격 테스트 장비의 고온 고장 처리
1083우시 구아냐 LNEYA 열충격 테스트 챔버의 전체 기능은 컴퓨터로 제어됩니다. 우수한 작동 인터페이스를 갖춘 자체 개발 소프트웨어로 사용자의 작동 및 모니터링을보다 간단하고 직관적으로 만듭니다. 메인 ...