100L high and low temperature thermostat installation instructions
The 100L high and low temperature thermostat uses coolant as the transmission medium to transfer the heat generated by other instruments or equipment that need to be cooled, and dissipate the heat to the outside of the equipment through the refrigeration system, so as to ensure that the equipment works within the normal temperature range. Between instruments and equipment, a closed medium circulation is formed by the pressure of the water pump in the device, and the temperature sensor detects the temperature of the medium to implement the control of the refrigerator.
The 100L high and low temperature thermostat is widely used in a variety of experimental equipment such as: rotary evaporator, x-ray diffractometer, lcp emission spectrometer, ICP mass spectrometer, graphite furnace atomic absorption spectrometer, fluorescence analyzer, electron microscope, production test equipment, CNC machine tools , Laser equipment, etc. This model is an integrated device. The condenser-compressor and evaporator-circulating water pump units are all installed in the same cabinet, and this type of unit is generally installed indoors.
The 100L high and low temperature thermostat should be installed in a laboratory with a good environment. The 100L high and low temperature integrated machine should be installed on a well-ventilated, dust-free and cool solid ground or a test bench to avoid droplets and steam, and avoid possible influx , Where there is stagnation, flammable gas leakage, and near equipment that generates high frequency.
Summarize
The 100L high and low temperature thermostat should avoid places where acidic solutions are frequently used, and places where special sprayers are frequently used. From the consideration of convenience and safety during maintenance and installation, the space between the indoor unit and obstacles should be ensured as much as possible.
관련 권장 사항
-
Operating instructions for the chiller, a laboratory process temperature control cycle system
1117The heat transfer medium of the laboratory process temperature control circulation system chiller uses oil and water. It uses electric heating to heat the heat transfer medium (heat transfer oil or water) that is forced to circulate in the pipelin...
세부 정보 보기 -
Cooling method for laboratory evaporative instruments in operation
958Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When pu...
세부 정보 보기 -
Working Principle of Glycol Chiller
1177For the low-temperature chiller using ethylene glycol solution, wecall it glycol chiller. Its outlet water temperature is generally below - 10 ℃, and the specific temperature requirements shall be subject to theneeds of users. Glycol chillers ar...
세부 정보 보기 -
High-pressure failure of stainless steel cryogenic refrigerator
1330At the high speed of the stainless steel cryogenic refrigerator compressor, the temperature rises and the compressor generates high air pressure, which causes the high voltage protection relay to operate. The discharge pressure of the compressor r...
세부 정보 보기