What Is the Range of Industrial Chiller Temperature Control
Industrial chiller is a common refrigeration equipment in industrial refrigeration industry,whose feature is various types, complete models and wide range of applications.More importantly, the precision of chiller temperature control is high and the ranger of it is wide.So,what is the range of industrial chiller temperature control and how to set it?
High temperature industrial chiller (5 ~ 30.0 ℃)
This kind of chiller can control the temperature between 5-30 ℃,using conventional refrigerants.In other words, when the chiller temperature control range is being adjusting,the set of the lowest temperature of the industrial chiller is 5℃ and the highest is 30℃.It is the most widely used temperature control range in the industry.
Medium temperature type industrial chiller (0 ~ 15.0 ℃)
Water freezes at 0 ℃.It is a common sense that old people and children can know.So,if industrial chiller is required to provide subzero cryogenic coolant,will it be realized?The answer is yes.The temperature of medium temperature industrial chiller can be set between 0 ℃ ~ 15 ℃.The refrigerant can be calcium chloride (saline) or ethylene glycol aqueous solution.
Low temperature industrial chiller
Low temperature industrial chiller which can provide (low temperature freezing liquid below -15℃~-35℃) is usually used in chemical industry and pharmaceutical industry for recycling material cooling or material in reaction kettle condensation.
Cryogenic type industrial chiller
Industrial cold chiller which can provide low temperature freezing liquid below 35 ℃, is called Cryogenic type industrial chiller.It adopts binary or ternary cascade refrigeration system, so it is also known as the cascade industrial chiller. Thus, the industrial chiller temperature control range is really wide.
Related recommendations
-
Function of Evaporator in Air Cooled Chiller
2036The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water qua...
View details -
Configuration form of circulating heating unit for laboratory
2016The standard model of the circulating heating unit for LNEYA laboratory is: SUNDI, the temperature range is from room temperature to minus 120 degrees Celsius, and the capacity can be divided into 5L, 10L, 20L, 30L, 40L, 50L, 80L, 100L, larger cap...
View details -
Heat transfer oil secondary circulation system use instructions
2109The thermal oil secondary circulation system is equipped with various instruments and equipment for temperature control. When using it, you need to pay attention to its safety knowledge and safer operation. LNEYA heat transfer oil secondary circul...
View details -
Common fuel cell environmental test device inspection method
2516During the cooling process of the fuel cell environmental test device, there is a chance of dripping inside. This is not a normal phenomenon used by the fuel cell environmental test device, but is caused by improper installation. After the fuel ce...
View details
LNEYA Thermo Refrigeration Co.,Ltd