Precautions for installing reactor refrigeration and heating circulator
The reactor refrigeration and heating cycle equipment can achieve high temperature of 200℃ and low temperature constant temperature test of -120℃, providing users with a field source with controlled thermal cooling and constant temperature. It can also be used as a heat source or cold source for direct heating, cooling, auxiliary heating, and auxiliary refrigeration. Source, temperature control within the full range, used in diffusion process control of semiconductor diffusion furnaces, constant temperature control or external circulation applications in reactors, fully automatic synthesis instruments, extraction and condensation devices.
Working principle of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment uses coolant as the heat transfer medium to transport the heat generated by other instruments or equipment that need to be cooled, and sends the heat to the outside of the equipment through the refrigeration system to ensure that the equipment works within the normal temperature range. The device and the instrument rely on the pressure of the pump in the device to form a closed medium circulation, and the temperature sensor is used to detect the temperature of the medium to realize the control of the cooler.
Installation environment of reactor refrigeration and heating cycle equipment:
The reactor refrigeration and heating cycle equipment has a semi-closed cycle. At high temperatures, no oil mist evaporates, and the thermal oil will not be oxidized and browned. At low temperatures, it will not absorb water vapor in the air, extending the life of the thermal oil. Reactor refrigeration and heating cycle equipment should be installed in a laboratory with a good environment; it should be installed on a well-ventilated, dust-free, stable floor or experimental table to avoid droplets, excess vapor, and possible inflow, stagnation, and leakage of flammable gases. Avoid places that can generate high-frequency equipment (high-frequency welding machines, etc.).
When the reactor refrigeration and heating cycle equipment avoids frequent use of acidic solutions and frequent use of special sprayers (containing sulfides, etc.), from the perspective of convenience and safety during maintenance and installation, try to ensure that there is a gap between the indoor unit and obstacles. have enough space.
Follow the instructions when installing:
The use of 300°C refrigeration and heating cycle equipment is inseparable from its standardized operation. When selling, there will be corresponding instructions for use when the equipment leaves the factory. Users can understand it in advance when using it.
The reactor refrigeration and heating cycle equipment is simple to install and operate, and does not require professional operation. The operator can be operated with simple training or by following the instructions; the heating method is circulating heating, so there is no loss of the medium; no need Annual review.
Summarize
The reactor refrigeration and heating cycle equipment is heated evenly, and the temperature adjustment adopts PID self-tuning intelligent control. The temperature control accuracy is ±1°C, which can meet the strict requirements of high process standards. Closed cycle heating, small heat loss, wide range of use.
SUNDI Z 주파수 변환 시리즈
WHATSAPP WECHAT Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion…
SUNDI -10℃~150℃
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ AC 380V 50HZ 8kW max Ultra high temperature cooling technology can directly cool from a hi…
SUNDI -80℃~250℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
SUNDI-320/320W
Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ Ultra-high Temperature Cooling Technology Can Directly Cool Down From 300℃ High Temperature. Bec…
SUNDI -25℃~200℃
완전 밀폐형 시스템, 단일 매체로 냉장 및 가열 완료 -120~350℃ ±0.5℃ ● 작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어...
SUNDI -25℃~300℃
작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
SUNDI -45℃~250℃
작동 온도 -120°C ~ +350°C● 이전에는 달성할 수 없었던 성능● 지능형 온도 제어● 최대 공정 안정성 및 재현성● 판형 열교환 기, 파이프 라인 가열, 가장 빠른 가열을 채택합니다 ...
SUNDI -60℃~250℃
Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion chamber contacts with ox…
loading…
이미 마지막 에피소드에 도달했습니다!
VIDEO
관련 권장 사항
-
SUNDI -45℃~250℃
1476작동 온도 -120°C ~ +350°C ● 이전에는 달성할 수 없었던 성능 ● 지능형 온도 제어 ● 최고의 공정 안정성 및 재현성 ● 판형 열교환기, 파이프라인 가열, 가장 빠른 열...
세부 정보 보기 -
Application Of Jacketed Reactor Cooling And Heating System In Chemical Reactions
594In the chemical industry, jacketed reactor cooling and heating devices are widely used in various chemical reactions. Application of jacketed reactor cooling and heating devices in various chemical reactions: Polymerization is a c...
세부 정보 보기 -
HR -25℃~200℃
1529The cooler is a very important part of the screw air compressor. The main function is to cool the lubricating oil of air compressor and the compressed air. If it's blocked, then the temperature will go up. A...
세부 정보 보기 -
KRY -25℃~+100℃
1478Temperature range is -25℃~+100℃, which can be extended to +135℃ according to the actual situation, and the temperature control accuracy is plus or minus 0.5℃. The equipment can control the flow and pressure independently w...
세부 정보 보기