제품 특징
제품 매개변수
Mode | AET-4025 AET-4025C |
AET-4050 AET-4050C |
AET-4095W AET-4095WC |
AET-7025 AET-7025C |
AET-7050W AET-7050WC |
AET-7095W AET-7095WC |
온도 범위 | -40℃~250℃ | -75℃~250℃ | ||||
온도 정확도 | Gas outlet temperature ± 0.1 ℃, remote process temperature precision ± 0.5 ℃ Optional gas temperature for mouth making and process target temperature |
|||||
Upgrade temp rate | The temperature rise and fall rate of the gas outlet of the equipment is greater than 30 ℃/min, and gradient temperature rise and fall can be performed |
|||||
Air requirements | Air filter < 5um, air oil content < 0.1um, air temperature and humidity: 5 ℃ -32 ℃ 0-50% RH pressure 4bar~8bar | |||||
Air handing | 22m³/h | 50m³/h | 95m³/h | 22m³/h | 50m³/h | 95m³/h |
스로틀링 방법 | Refrigeration system adopts electronic expansion valve throttling to precisely control the cooling capacity | |||||
컨트롤러 | PLC programmable controller, standard support for ModbusRTU protocol, RS485 interface, Optional other communication protocols |
|||||
Display Records | 7-inch color touch screen, display gas temperature, pressure, flow rate, refrigeration system pressure and temperature | |||||
프로세스 온도 제어 | 원격 목표 온도는 자체 생성 된 모델 무료 자체 구축 트리를 결합하여 제어 할 수 있습니다. 알고리즘 및 캐스케이드 알고리즘 |
|||||
치수 cm | 43*46*112 | 52*57*132 | 60*63*160 | 54*69*112 | 65*85*132 | 75*95*160 |
Remarks | The suffix W represents water cooling The suffix c represents gas recycling |
정격 시험 조건: 건구 온도 20℃, 습구 온도 16℃. 입구수 온도 20℃, 출구수 온도 25℃.
이 표의 데이터는 참고용입니다. 장치 명판의 매개변수를 참조하십시오.
If you need special non-standard customization, please contact our company
온도 제어 공급업체로 엘니야를 선택하는 이유는 무엇인가요?
18+
수년간의 경험
30000+
만족한 고객
25000
m² 생산 면적
80+
특허 기술
LNEYA 공장 방문