How to Prolong the Service Life of Glycol Chiller System?
In order to extend the service life of your glycol chiller in industrial applications, please pay attention to the following points:
1. Use automobile grade antifreeze carefully
Do not use automobile grade or unqualified antifreeze. Because this glycol is not manufactured for industrial applications, it may cause a variety of problems and shorten the service life of your glycol chiller system.
2. Comply with local regulations.
Experts have designed different rules and regulations according to the environmental requirements of this specific area. These are called local regulations, which not only provide safe operation, but also prolong the service life of ethylene glycol chiller system for your industrial application.
3. Fluid filtration and equipment maintenance.
Another secret to prolong the service life of ethylene glycol chiller system is to use fluid filter and carry out fluid maintenance. Operate the equipment as specified in the manufacturer’s manual.
4. Perform all preventive and corrective maintenance.
All planned and unplanned maintenance must be performed to extend the service life of the glycol chiller system· Provide regular maintenance list for all users, such as cleaning, lubrication, dust removal and filter replacement. All inspections are completed in time according to the instructions in the manufacturer’s manual.
5. On time calibration of equipment.
Stickers are attached to all equipment requiring calibration. This shows the calibration date, all of which should be calibrated in time to improve the efficiency of the measuring instrument and prolong the service life of your glycol cooling system.
Related recommendations
-
Temperature control of integrated circuit/chip wafer quality and reliability test items
2546The most basic part of making a chip is design-tape-package-test. The chip cost structure is generally 20% of labor cost, 40% of tape, 35% of package, and 5% of test. The test is actually the most in all aspects of the chip. "Cheap" step, but the...
View details -
Aerospace equipment parts cryogenic test freezer refrigeration troubleshooting instructions
2253Cooling water inlet temperature is too low Ultra-low temperature freezer for ultra-low temperature testing of aerospace equipment components As the temperature of the cooling water decreases, the compressor discharge pressure, exhaust temperature,...
View details -
Thermal oil heating system installation and fault analysis
2424When the heat transfer oil heating system device is installed, it is necessary to pay attention to the system to avoid some faults during installation. If a fault occurs, it is necessary to understand the faults related to the heat transfer oil he...
View details -
Structural Characteristics of Industrial Recirculating Chiller
1813In the chemical reaction, there are strict requirements for the reaction temperature. It is necessary to raise the temperature to an appropriate temperature to carry out the chemical reaction smoothly. After the reaction, the temperature in the re...
View details
LNEYA Thermo Refrigeration Co.,Ltd