뉴스

LNEYA 냉온수기 SUNDI 매뉴얼
The temperature range of the hot and cold machine ranges from -120 ° C to 350 ° C. It has superior performance and unique performance. It has high precision and intelligent temperature control. The high cooling power is from 0.5 to 1200 kW. High production stability and repeatability result. Functional alarm system and safety functions, using plate heat exchangers, ducted heaters to increase heating and cooling rates. The hot and cold machine adopts 7-inch, 10-inch color TFT touch screen grap...
세부 정보 보기
배터리 테스트 장비의 온도 제어 중 냉각 용량에 영향을 미치는 요인
Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For example, the small battery test equipment is piston type, and the medium type is optional. Scroll type. When the water temperature of the battery test equipment (the evaporation temperature is different, the cooling capacity is different), the higher...
세부 정보 보기
신에너지 차량 배터리 테스트 시스템에서 냉매의 중요성
If the flow rate of the refrigerant in the new energy vehicle battery test system is extremely small, the refrigerant will start to expand from the first expandable space at the rear end of the throttle valve. Most of the see-up of the rear end of the expansion valve is often due to lack of cooling. Or the expansion valve flow is not enough, too little refrigerant expansion will not use all the evaporator area, only the low temperature is formed locally in the evaporator, and some areas are r...
세부 정보 보기
고온 및 저온 습열 테스트 장치의 압축기에 대한 설명
Different types of compressors for high and low temperature damp heat test devices often have an impact on price. When choosing, we should choose low-energy refrigeration compressors as much as possible. Now China is paying more and more attention to energy conservation and emission reduction, we must also make our own efforts. Doing this, and the loss of machinery is not much of a benefit to us, and the other is to choose less noise, so as not to affect our rest. High and low temperature dam...
세부 정보 보기
모터 냉각 시스템이 응축 온도에 미치는 영향 테스트
The motor cooling system tests the condenser. Under normal conditions, the first half of the heat pipe is very hot, and its temperature has a slow and slow gradual decline in the balance of power. The heat sensitivity of the second half of the heat pipe is greatly reduced compared with the first half. It is because the refrigerant in the second half of the tube has gradually liquefied, and the condensation temperature and the supercooling temperature have been reached. When the motor cooling ...
세부 정보 보기
수직형 초저온 냉장고의 열전달 효과가 감소하는 이유
If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it can be caused because the external temperature of the evaporator is mostly lower than 0 °C, resulting in low heat transfer efficiency of the evaporator. Because the vertical ultra-low temperature refrigerator has relatively high humidity, the moisture in the air is easy to frost on the surface of the evaporator, and even freezes, which affects the heat transfer effect of the evapo...
세부 정보 보기
반도체 냉장 온도 제어 테이블 쿨러 작동 지침
반도체 냉동 온도 제어 스테이션의 변압기 냉각 시스템 제어 시스템의 전원 공급 장치 스위칭은 수입 된 이중 전원 자동 스위칭 장치를 사용합니다. 주요 기능은 활성 및 대기 작동 전원 간의 자동 전환입니다. 일반적인 정전이 발생하면 자동으로 대기 전원 공급 장치로 전환됩니다. 두 전원 공급 장치가 모두 정상이면 공통 전원 공급 장치가 작동하고 대기 전원 공급 장치가 대기 상태에 있습니다.
세부 정보 보기
다단계 냉동 시스템 원심 컴프레서 수리 지침
캐스케이드 냉동 시스템의 원심 압축기를 분해한 후 각 저널(임펠러, 베어링, 커플링 등과 협력)의 치수를 외경 마이크로미터로 측정하여 진원도 및 원통도 편차를 계산합니다. 이 값은 허용 범위 내에 있어야 합니다. 공차가 큰 경우 스핀들의 직진도 편차가 너무 큰지 확인합니다. 스핀들을 케이스에 넣거나 선반 상단에 배치하여 ...
세부 정보 보기
배터리 테스트 수냉식 냉각기 상식 설명
배터리 테스트 수냉식 공기 흡입구 과열이 없는 경우 액체가 포함된 리턴 공기가 있을 수 있으며 습식 스트로크 액체 충격이 발생하여 컴프레서가 손상될 수도 있습니다. 이러한 현상을 방지하기 위해 어느 정도의 흡입 과열이 필요하여 건조한 증기만 컴프레서에 유입되도록 합니다(과열이 있다는 것은 냉매의 특성으로 인해 액체 냉매가 완전히 증발했음을 나타냅니다). 그러나 배터리 테스트 워터 쿨러의 과열이 너무 높아서 ...
세부 정보 보기