LNEYA 냉온수기 SUNDI 매뉴얼

LNEYA 냉온수기 SUNDI 매뉴얼

The temperature range of the hot and cold machine ranges from -120 ° C to 350 ° C. It has superior performance and unique performance. It has high precision and intelligent temperature control. The high cooling power is from 0.5 to 1200 kW. High production stability and repeatability result. Functional alarm system and safety functions, using plate heat exchangers, ducted heaters to increase heating and cooling rates. The hot and cold machine adopts 7-inch, 10-inch color TFT touch screen grap...

세부 정보 보기
온도 상승 시 냉각 용량에 영향을 미치는 요인 ...

배터리 테스트 장비의 온도 제어 중 냉각 용량에 영향을 미치는 요인

Battery Test Equipment Refrigeration System The greater the power of the battery test equipment compressor, the higher the cooling capacity. According to the size of the battery test equipment, the compressors of different types are selected. For example, the small battery test equipment is piston type, and the medium type is optional. Scroll type. When the water temperature of the battery test equipment (the evaporation temperature is different, the cooling capacity is different), the higher...

세부 정보 보기
새로운 에너지 차량에서 냉매의 중요성 ...

신에너지 차량 배터리 테스트 시스템에서 냉매의 중요성

If the flow rate of the refrigerant in the new energy vehicle battery test system is extremely small, the refrigerant will start to expand from the first expandable space at the rear end of the throttle valve. Most of the see-up of the rear end of the expansion valve is often due to lack of cooling. Or the expansion valve flow is not enough, too little refrigerant expansion will not use all the evaporator area, only the low temperature is formed locally in the evaporator, and some areas are r...

세부 정보 보기
고압 및 저압의 압축기에 대한 설명 ...

고온 및 저온 습열 테스트 장치의 압축기에 대한 설명

Different types of compressors for high and low temperature damp heat test devices often have an impact on price. When choosing, we should choose low-energy refrigeration compressors as much as possible. Now China is paying more and more attention to energy conservation and emission reduction, we must also make our own efforts. Doing this, and the loss of machinery is not much of a benefit to us, and the other is to choose less noise, so as not to affect our rest. High and low temperature dam...

세부 정보 보기
Motor cooling system tests the effect of conden...

모터 냉각 시스템이 응축 온도에 미치는 영향 테스트

The motor cooling system tests the condenser. Under normal conditions, the first half of the heat pipe is very hot, and its temperature has a slow and slow gradual decline in the balance of power. The heat sensitivity of the second half of the heat pipe is greatly reduced compared with the first half. It is because the refrigerant in the second half of the tube has gradually liquefied, and the condensation temperature and the supercooling temperature have been reached. When the motor cooling ...

세부 정보 보기
Auxiliary equipment for LNEYA glass reactor system
Reasons for the decrease of heat transfer effec...

수직형 초저온 냉장고의 열전달 효과가 감소하는 이유

If the outer frost layer of the vertical ultra-low temperature refrigerator is too thick or excessively dusty, it can be caused because the external temperature of the evaporator is mostly lower than 0 °C, resulting in low heat transfer efficiency of the evaporator. Because the vertical ultra-low temperature refrigerator has relatively high humidity, the moisture in the air is easy to frost on the surface of the evaporator, and even freezes, which affects the heat transfer effect of the evapo...

세부 정보 보기
반도체 냉장 온도 제어...

반도체 냉장 온도 제어 테이블 쿨러 작동 지침

반도체 냉동 온도 제어 스테이션의 변압기 냉각 시스템 제어 시스템의 전원 공급 장치 스위칭은 수입 된 이중 전원 자동 스위칭 장치를 사용합니다. 주요 기능은 활성 및 대기 작동 전원 간의 자동 전환입니다. 일반적인 정전이 발생하면 자동으로 대기 전원 공급 장치로 전환됩니다. 두 전원 공급 장치가 모두 정상이면 공통 전원 공급 장치가 작동하고 대기 전원 공급 장치가 대기 상태에 있습니다.

세부 정보 보기
120도 울트라 울트라에서 오일 부족은 무엇입니까?

120도 초저온 냉장고에 오일이 부족한 이유는 무엇인가요?

120도 초저온 냉장고의 컴프레서는 고속으로 작동하는 복잡한 부품입니다. 압축기 크랭크 샤프트, 베어링, 커넥팅로드, 피스톤 등의 움직이는 부품에 충분한 윤활을 보장하기 위해 -120도 초저온 냉장고의 정상적인 작동을 유지하기위한 기본 요구 사항입니다. 따라서 우시 유제는 120도 초저온 냉장고 제조업체가 설계를 사용해야한다고 제안했습니다.

세부 정보 보기
다단 냉동 소형 온도 조절기 ...

다단 냉동 소형 온도 제어 컴프레서 설명

다단 냉동 소형 온도 제어 스테이션 시스템에서 컴프레서의 기능은 증발기의 냉매 증기를 끌어와 온도와 압력을 높여 응축기로 배출하는 것입니다. 콘덴서에서는 고압 과열된 냉매 증기가 콘덴서 온도에서 응축됩니다. 그런 다음 스로틀 링 요소를 통해 천연 가스가 환원 된 후 액체 혼합물이 증발기로 유입되고 냉매 액체가 흡수됩니다 ...