Search the whole station

  • 5L glass reactor thermal oil heating system

    1773

    5L glass reactor is a common laboratory equipment used for various chemical reactions. In order to ensure that the reaction is carried out at the required temperature, it is usually necessary to equip it with a heating system. Thermal oil (also kn...

    View details
  • Hot & Cold Dual Circuit Temp Control Units

    3706

    INQUIRY Remote control 100% helium detection 100% safety regulations Frequency regulation Hot and cold dual-channel Hot test 80°C~125°℃ For 120°C high temperature heating and dryingCold test -15°c~30°℃ The other side is used for cooling and captur...

    View details
  • KRYZ Frequency Conversion Series

    4864

    INQUIRY Air-cooling & Water-cooling Configuration Details Model KRYZ-475KRYZ-475W KRYZ-4A15W KRYZ-4A25W Temperature range -40℃~+100℃ Temperature control accuracy ±0.1℃ ±0.1℃ ±0.1℃ Temperature feedback Pt100 Pt100 Pt100 Temperature display 0.0...

    View details
  • Deionized Water Chiller

    5587

    DI Pure water Cooling unit Suitable for the production process of 2°℃~5°CDI water demand. Normal temperature Dl water enters the temperature control unit, and the target temperature D1 water is output, which solves the problem of easy freezing of ...

    View details
  • LTZ Variable Frequency M series

    4605

    It is suitable for the target temperature control object that already has a cold storage tank and a circulating pump. The medium is transported to the LTZ M series refrigeration unit through the circulating pump, which is a closed-loop refrigerati...

    View details
  • LTG Screw Chiller Units

    4429

    It is suitable for various production process cold sources in chemical, pharmaceutical, machinery and other fields, and can provide -110℃~30℃ refrigeration medium, which can be used as ice storage, low temperature air supply and other process cold...

    View details
  • Low Temperature Freezer GD series -150℃

    4975

    Ultra-low temperature freezer/refrigerators for bearing cold assembly GD -150℃~-110℃ Storage Capacity 1100L Temperature fluctuation±0.5℃ RefrigeratentR404A R23/Mixed refrigerant Place of OriginChina Microcomputer control, cascade temperature contr...

    View details
  • DR Series

    4169

    Additional filtration of oil and particulate matter, the air flow passes through a pre-filter with a filtration grade of 0.01 μm to prevent the desiccant from being contaminated by dust and oil (oil will greatly shorten the service life of the des...

    View details
  • ZLT HED Series

    4810

    This device can directly introduce chemical media and accurately control temperature, serving as Preheating, pre cooling and temperature control of the medium before chemical reaction. Chemical media include hydrofluoric acid, sulfuric acid, ammon...

    View details
Expand more!