LTS -40℃~35℃
Temperature control during semiconductor manufacturing- 흐름 제어12L/min~45L/min
- 온도 정확도±0.1℃ @40℃~-10℃
- Internal circulating liquid4L~10L
- 확장 탱크10L~20L
- 원산지중국
제품 데이터 다운로드
세부 매개 변수
모델
|
LTS-402
|
LTS-403
|
LTS-404
|
LTS-406
|
LTS-408
|
LTS-402W
|
LTS-403W
|
LTS-404W
|
LTS-406W
|
LTS-408W
|
|
온도 범위
|
-40℃~35℃
|
||||
온도 제어 정확도
|
±0.1℃ -40℃~-10℃
|
||||
흐름 제어
|
7~25L/min
|
12~45L/min
|
|||
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
|
|||||
Internal circulating fluid volume
|
4L
|
5L
|
6L
|
8L
|
10L
|
확장 탱크 용량
|
10L
|
10L
|
15L
|
15L
|
20L
|
시스템 압력 표시
|
The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
|
||||
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
|
|||||
컨트롤러
|
PLC, 퍼지 PID 제어 알고리즘, 캐스케이드 제어 알고리즘 포함
|
||||
온도 제어
|
열전달 매체 출구 온도 제어 모드
|
||||
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
|
|||||
계약서
|
이더넷 인터페이스 TCP/IP 프로토콜
|
||||
RS485 인터페이스 모드버스 RTU 프로토콜
|
|||||
Internal temperature feedback of equipment
|
Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
|
||||
폐쇄형 순환 시스템
|
The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
|
||||
압축기
|
Emerson Copeland/Danfoss Scroll Flexible Compressor
|
||||
순환 펌프
|
Magnetic circulation pump
|
||||
증발기
|
판형 열교환기
|
||||
콘덴서
|
Micro channel condenser (air-cooled)
|
||||
Plate heat exchanger (water-cooled), special attention: clean factory water is required
|
|||||
냉장 액세서리
|
Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
|
||||
조작 패널
|
Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
|
||||
보안
|
With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
|
||||
인/아웃 인터페이스 크기
|
ZG1/2
|
ZG1/2
|
ZG3/4
|
ZG3/4
|
ZG3/4
|
제품 설명
It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.
1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
온도 샘플링 및 응답 속도를 최적화하고 제어 알고리즘을 특별히 설계하여 안정적인 온도 제어에 신속하게 대응할 수 있습니다.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.

다음 제품에도 관심이 있을 수 있습니다.
MD 시리즈 척
-75℃ ~ 225°C 모델 MD-708 MD-712 MDL-708 온도. 범위 -75℃~225℃ -75℃~225℃ -75℃~225℃ 온도 제어 정확도 ±0.1℃ ±0.1℃ 온도 균일성 ±1℃ ±1℃ ±1℃ 평탄도 ±50um ±50um 정제 크기 직경 200mm d ...
YQH 0℃~-75℃
다양한 휘발성 VOCs 가스 회수에 적합; 빠른 냉각, 고효율, 다양한 응축 온도 요구 사항 충족, 저온 -75 ° C 도달 가능 주로 청소, 접착제에서 비롯됩니다 ...
FLT-100℃~90℃
주로 에칭 장비용으로 설계된 단일 채널 공랭식 쿨러입니다. 챔버 측벽에 독립적인 온도 제어를 제공하는 데 사용됩니다.
FLTZ -45℃~90℃
40 ℃ 이내의 가열 방식은 압축기 고온 가스 가열 완전 밀폐형 설계를 채택하고 기계는 24 시간 연속 작동 반도체 온도 제어 장치 칠러는 주로 ...
로딩 중...
이미 마지막 에피소드에 도달했습니다!